MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2023.10.034

Медицинская библиотека · Journal of the American College of Cardiology · 2024

Rethinking False Positive Exercise Electrocardiographic Stress Tests by Assessing Coronary Microvascular Function.

Sinha Aish, Dutta Utkarsh, Demir Ozan M, De Silva Kalpa, Ellis Howard, Belford Samuel, Ogden Mark, Li Kam Wa Matthew, Morgan Holly P, Shah Ajay M, Chiribiri Amedeo, Webb Andrew J, Marber Michael, Rahman Haseeb, Perera Divaka

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Exercise electrocardiographic stress testing (EST) has historically been validated against the demonstration of obstructive coronary artery disease. However, myocardial ischemia can occur because of coronary microvascular dysfunction (CMD) in the absence of obstructive coronary artery disease.

OBJECTIVES

The aim of this study was to assess the specificity of EST to detect an ischemic substrate against the reference standard of coronary endothelium-independent and endothelium-dependent microvascular function in patients with angina with nonobstructive coronary arteries (ANOCA).

METHODS

Patients with ANOCA underwent invasive coronary physiological assessment using adenosine and acetylcholine. CMD was defined as impaired endothelium-independent and/or endothelium-dependent function. EST was performed using a standard Bruce treadmill protocol, with ischemia defined as the appearance of ≥0.1-mV ST-segment depression 80 ms from the J-point on electrocardiography. The study was powered to detect specificity of ≥91%.

RESULTS

A total of 102 patients were enrolled (65% women, mean age 60 ± 8 years). Thirty-two patients developed ischemia (ischemic group) during EST, whereas 70 patients did not (nonischemic group); both groups were phenotypically similar. Ischemia during EST was 100% specific for CMD. Acetylcholine flow reserve was the strongest predictor of ischemia during exercise. Using endothelium-independent and endothelium-dependent microvascular dysfunction as the reference standard, the false positive rate of EST dropped to 0%.

CONCLUSIONS

In patients with ANOCA, ischemia on EST was highly specific of an underlying ischemic substrate. These findings challenge the traditional belief that EST has a high false positive rate.

Для цитирования: Sinha Aish, Dutta Utkarsh, Demir Ozan M, De Silva Kalpa, Ellis Howard, Belford Samuel, Ogden Mark, Li Kam Wa Matthew, Morgan Holly P, Shah Ajay M, Chiribiri Amedeo, Webb Andrew J, Marber Michael, Rahman Haseeb, Perera Divaka. Rethinking False Positive Exercise Electrocardiographic Stress Tests by Assessing Coronary Microvascular Function.. Journal of the American College of Cardiology. 2024. DOI: 10.1016/j.jacc.2023.10.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.