MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.ju.0000165345.11199.98

Медицинская библиотека · The Journal of urology · 2005

The current role of the artificial urinary sphincter for the treatment of urinary incontinence.

Hussain Mahreen, Greenwell Tamsin J, Venn Suzie N, Mundy Anthony R

СтатьяОбзорПеревод в очереди

Аннотация

PURPOSE: The introduction of the artificial urinary sphincter (AUS) in 1972 was heralded as a revolution for the treatment of genuine stress incontinence. Initial enthusiasm was tempered by disappointment as complications occurred. The device has now been in routine clinical use for more than 30 years, and the indications and surgical principles involved in its use along with short-term and long-term outcomes are more clearly defined. Hence, we reviewed the literature to clarify the role of the AUS and offer a possible solution to its problems in the guise of a new sphincter.

MATERIALS AND

METHODS

A MEDLINE search was performed and all articles relating to the role of the AUS for the treatment of urinary incontinence were reviewed.

RESULTS

The AMS 800 (American Medical Systems, Minnetonka, Minnesota) provides urinary continence in 73% of cases (range 61% to 96%) and it has a complication rate of 12% (range 3% to 33%) for mechanical failure, 4.5% to 67% for early infection/erosion, 15% for late erosion and 7% for delayed recurrent incontinence. The literature supports the role of the AUS as an important and reliable treatment modality for stress urinary incontinence and intrinsic sphincter deficiency. However, it is not suitable in all patients and its use for the management of hypermobility is controversial. Hence, careful patient selection according to indication is required with full preoperative counseling.

CONCLUSIONS

Despite its reliability for achieving urinary continence the AMS 800 is not perfect. Newer devices, such as that being developed at our institution, may offer improved outcomes and decreased complication rates.

Для цитирования: Hussain Mahreen, Greenwell Tamsin J, Venn Suzie N, Mundy Anthony R. The current role of the artificial urinary sphincter for the treatment of urinary incontinence.. The Journal of urology. 2005. DOI: 10.1097/01.ju.0000165345.11199.98.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.