Wolfrum Mathias, Handerer Immanuel Justus, Moccetti Federico, Schmeisser Alexander, Braun-Dullaeus Ruediger C, Toggweiler Stefan

Аннотация

BACKGROUND: The Sentinel cerebral embolic protection device (CEP) aims to reduce the risk of stroke during transcatheter aortic valve replacement (TAVR). We performed a systematic review and meta-analysis of propensity score matched (PSM) and randomized controlled trials (RCT) investigating the effect of the Sentinel CEP to prevent strokes during TAVR.

METHODS: Eligible trials were searched through PubMed, ISI Web of science databases, Cochrane database, and proceedings of major congresses. Primary outcome was stroke. Secondary outcomes included all-cause mortality, major or life-threatening bleeding, major vascular complications and acute kidney injury at discharge. Fixed and random effect models were used to calculate the pooled risk ratio (RR) with 95% confidence intervals (CI) and absolute risk difference (ARD).

RESULTS: A total of 4066 patients from 4 RCTs (3'506 patients) and 1 PSM study (560 patients) were included. Use of Sentinel CEP was successful in 92% of patients and was associated with a significantly lower risk of stroke (RR: 0.67, 95% CI: 0.48-0.95, p = 0.02. ARD: -1.3%, 95% CI: -2.3 - -0.2, p = 0.02, number needed to treat (NNT) = 77), and a reduced risk of disabling stroke (RR: 0.33, 95% CI: 0.17-0.65. ARD: -0.9%, 95% CI: -1.5 - -0.3, p = 0.004, NNT = 111). Use of Sentinel CEP was associated with a lower risk of major or life-threatening bleeding (RR: 0.37, 95% CI: 0.16-0.87, p = 0.02). Risk for nondisabling stroke (RR: 0.93, 95% CI: 0.62-1.40, p = 0.73), all-cause mortality (RR: 0.70, 95% CI: 0.35-1.40, p = 0.31), major vascular complications (RR: 0.74, 95% CI: 0.33-1.67, p = 0.47) and acute kidney injury (RR: 0.74, 95% CI: 0.37-1.50, p = 0.40) were similar.

CONCLUSIONS: The use of CEP during TAVR was associated with lower risks of any stroke and disabling stroke with an NNT of 77 and 111, respectively.