DOI 10.1097/md.0000000000037248
Coxsackie B virus-induced myocarditis in a patient with a history of lymphoma: A case report and review of literature.
Аннотация
INTRODUCTION
In rare occasions, coxsackievirus infections can cause serious illness, such as encephalitis and myocarditis. The immunotherapies of cancer could increase the risk of myocarditis, especially when applying immune checkpoint inhibitors. Herein, we report a rare case of Coxsackie B virus-induced myocarditis in a patient with a history of lymphoma.
CASE PRESENTATION: A 32-year-old woman was admitted to the hospital with recurrent fever for more than 20 days, and she had a history of lymphoma. Before admission, the positron emission tomography/computed tomography result indicated that the patient had no tumor progression, and she was not considered the cancer-related fever upon arriving at our hospital. Patient's red blood cell, platelet count, and blood pressure were decreased. In addition, she had sinus bradycardia and 3 branch blocks, which was consistent with acute high lateral and anterior wall myocardial infarction. During hospitalization, the patient had recurrent arrhythmia, repeated sweating, poor mentation, dyspnea, and Coxsackie B virus were detected in patient's blood samples by pathogen-targeted next-generation sequencing. The creatine kinase, creatine kinase MB, and N-terminal pro-brain natriuretic peptide were persistently elevated. Consequently, the patient was diagnosed with viral myocarditis induced by Coxsackie B virus, and treated with acyclovir, gamma globulin combined with methylprednisolone shock therapy, trimetazidine, levosimendan, sildenan, continuous pump pressors with m-hydroxylamine, entecavir, adefovir, glutathione, pantoprazole, and low-molecular-weight heparin. Her symptoms worsened and died.
CONCLUSION
We reported a case with a history of lymphoma presented with fever, myocardial injury, who was ultimately diagnosed with Coxsackie B virus-induced myocarditis. Moreover, pathogen-targeted next-generation sequencing indeed exhibited higher sensitivity compared to mNGS in detecting Coxsackie B virus.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.