m+Medelevator.RU
← Поиск публикаций
Archives of gynecology and obstetrics · 2022

Impact of maternal body mass index on the accuracy of third trimester sonographic estimation of fetal weight.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gevaerd Martins Juliana, Kawakita Tetsuya, Jain Priyanka, Gurganus Margot, Baraki Dana, Barake Carole, Sinkovskaya Elena, Abuhamad Alfred

Аннотация

OBJECTIVES: To Determine whether maternal body mass index (BMI) can affect the accuracy of sonographic estimation of fetal weight (EFW) in the third trimester when compared to neonatal birthweight (BW).

METHODS: Secondary analysis from our original prospective cohort of pregnant women beyond 34 weeks, distributed in 4 groups according to their BMI: normal, overweight, obese and morbid obese. Fetal biometry and fluid measurements were obtained by two experienced sonographers, blinded for patient's clinical information and to each other's measurements. Average EFW and neonatal BW were converted into gestational-specific Z-scores. Interobserver correlation coefficient (ICC) and Cronbach's reliability coefficient (CRC) were calculated. Bland-Altman (BA) plots were constructed to assess the level of accuracy.

RESULTS: 100 women were enrolled (800 measurements obtained by 17 sonographers): 17 had normal BMI (17%), 27 were overweight (27%), 29 were obese (29%) and 27 were morbidly obese (27%). There was no statistical difference for GA at delivery (p = 0.74), EFW (p = 0.05) or BW (p = 0.09) between groups (Table 1). Mean Z-score for EFW was - 0.17 (SD 0.81) and for neonatal BW was - 0.25 (SD 0.74). ICC was 0.69 (95% CI 0.57, 0.78) and CRC was 0.82. Mean Z-score difference was small (Table 2). When stratifying according to BMI categories, the ICC ranged from 0.49 to 0.76. Reliability indices ranged from 0.66 to 0.86. The Z-scores' differences were overall small with no statistical difference (Table 3). BA showed evenly distributed interobserver differences (Fig. 1).

CONCLUSIONS: When performed by trained sonographers, fetal weight estimation in the third trimester is accurate when compared to neonatal birthweight at increasing BMI categories.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты