MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jmas.jmas_2_23

Медицинская библиотека · Journal of minimal access surgery · 2024

A comparative study of indocyanine green instillation in inguinal node versus foot web space using da Vinci indocyanine green FireFly™ technology in identifying thoracic duct during robotic-assisted transthoracic oesophagectomy.

Somashekhar S P, Saldanha Elroy, Kumar Rohit, Monteiro Ashma, Pillarisetti Sai Ram, Ashwin K R

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Chyle leak is a serious complication following oesophagectomy with incidence varies from 1% to 9%. Near infra-red fluorescence imaging of thoracic duct (TD) can provide real-time dynamic imaging during the surgery. In this study, we intend to compare indocyanine green (ICG) dye instillation through inguinal node with subcutaneous first web space instillation for visualisation of TD during robotic-assisted minimally invasive oesophagectomy (RAMIE) procedure.

PATIENTS AND

METHODS

A prospective study of 50 patients underwent RAMIE with da Vinci X System. After general anaesthesia, patients were divided into inguinal node and foot first web space ICG instillation group. The former group had 1 ml of ICG dye instilled on bilateral inguinal nodes under ultrasound guidance and while the other group received 1 mL of ICG dye injected at bilateral foot first web space and then underwent surgery. TD was visualised using ICG FireFly™ fluorescence technology, first at the time of docking and subsequently for every 5 min until 60 min of instillation time and analysed.

RESULTS

Twenty-five patients were enrolled in each group. The mean docking time for thoracic phase was 13.76 ± 3.43 min. TD was visualised in 72% (18/25) of cases of first web space instillation group, whereas 100% in ultrasound guidance inguinal node instillation group. None of the patients had a chyle leak.

CONCLUSION

ICG FireFly™ fluorescence technology for the identification of TD during oesophageal mobilisation is safe and effective and provides real-time dynamic visualisation with high accuracy in ultrasound-guided bilateral inguinal node instillation group. It is an effective method for the surgeons planning to negotiate their initial learning curve in RAMIE procedures.

Для цитирования: Somashekhar S P, Saldanha Elroy, Kumar Rohit, Monteiro Ashma, Pillarisetti Sai Ram, Ashwin K R. A comparative study of indocyanine green instillation in inguinal node versus foot web space using da Vinci indocyanine green FireFly™ technology in identifying thoracic duct during robotic-assisted transthoracic oesophagectomy.. Journal of minimal access surgery. 2024. DOI: 10.4103/jmas.jmas_2_23.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление