Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2026
[Safety study of resin-based dental materials using gas chromatography-mass spectrometry techniques].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Li Yujie, Zeng Yiyong, Du Zhenxia, Ren Guifang
Аннотация
OBJECTIVES: To investigate the clinical application safety of dental adhesives and composite resin-based dental materials.
METHODS: A non-targeted screening of migrants from clinically used dentin adhesives and composite resin materials was conducted using gas chromatography-mass spectrometry (GC-MS). Migration media included saliva simulants with pH of 5.5, 6.2, 7.4, and 8.0, 50% ethanol solution, and ultrapure water. By simulating migration under va-rious oral environments, six migrants were detected in the migration media. GC-MS/flame ionization detector was used for quantitative analysis of these migrants, and risk assessment was performed by combining their toxicity data.
RESULTS: In all six migration media, the exposure levels of monomers and photoinitiators released from four commercially avai-lable resin-based dental materials were all within established safety thresholds.
CONCLUSIONS: This study conducted nontargeted detection and safety assessment of migrants from dental restorative materials. The exposure levels of all detected compounds were below safety limits, providing scientific evidence supporting the clinical safety of composite resin-based dental materials.
METHODS: A non-targeted screening of migrants from clinically used dentin adhesives and composite resin materials was conducted using gas chromatography-mass spectrometry (GC-MS). Migration media included saliva simulants with pH of 5.5, 6.2, 7.4, and 8.0, 50% ethanol solution, and ultrapure water. By simulating migration under va-rious oral environments, six migrants were detected in the migration media. GC-MS/flame ionization detector was used for quantitative analysis of these migrants, and risk assessment was performed by combining their toxicity data.
RESULTS: In all six migration media, the exposure levels of monomers and photoinitiators released from four commercially avai-lable resin-based dental materials were all within established safety thresholds.
CONCLUSIONS: This study conducted nontargeted detection and safety assessment of migrants from dental restorative materials. The exposure levels of all detected compounds were below safety limits, providing scientific evidence supporting the clinical safety of composite resin-based dental materials.