MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2005.05.008

Медицинская библиотека · Injury · 2005

Functional outcome of tibial plateau fractures treated with the fine-wire fixator.

Chin Terence Y P, Bardana David, Bailey Michael, Williamson Owen D, Miller Russell, Edwards Elton R, Esser Max P

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To review the functional outcome of patients with complex tibial plateau fractures treated with fine-wire fixation.

DESIGN

Retrospective review with follow-up of patients in outpatient clinic.

SETTING

Tertiary trauma center.

PATIENTS: All patients who had fine-wire fixation for tibial plateau fractures between 1996 and January 2001 were reviewed.

INTERVENTIONS: Fine-wire fixation with/without limited internal fixation for complex tibial plateau fractures.

MAIN OUTCOME MEASURES: Knee range of motion, adequacy of articular surface reduction, mechanical axis, Knee Society Clinical Rating Scale and Short-Form 36 Health Questionnaire.

RESULTS

Eighteen of twenty-one eligible patients were available for follow-up. There were 14 Shatzker VI and 4 V fractures. Seven fractures were open. Average follow-up was 28.2 months. All fractures united. There were three cases of delayed union, all progressed to union following additional procedures and bone grafting. There were no cases of osteomyelitis, septic arthritis or deep vein thrombosis. Seven patients had Knee Society Clinical Rating Scores of good/excellent (38.9%), and 11 had fair/poor scores (61.1%). Abnormal mechanical axes and multiple co-morbid injuries were associated with poorer outcomes. Although SF-36 scores were lower in the study group compared to matched population norms, 15 of 18 patients had full or partial return to pre-injury levels of functioning.

CONCLUSION

Fine-wire fixation with limited internal fixation is a satisfactory method of managing complex high-energy fractures of the tibial plateau where soft tissue injury and bony comminution make traditional techniques of open reduction and internal fixation unsuitable.

Для цитирования: Chin Terence Y P, Bardana David, Bailey Michael, Williamson Owen D, Miller Russell, Edwards Elton R, Esser Max P. Functional outcome of tibial plateau fractures treated with the fine-wire fixator.. Injury. 2005. DOI: 10.1016/j.injury.2005.05.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.