DOI 10.1093/bjr/tqag157

Медицинская библиотека · The British journal of radiology · 2026

Utility of High-Resolution Semiconductor Positron Emission Tomography/Computed Tomography in the Assessment of Breast Cancer Extent: Comparison with Magnetic Resonance Imaging.

Miyamoto Akina, Yoshizako Takeshi, Kuroda Hiroyuki, Yoshida Rika, Yamamoto Nobuko, Kaji Yasushi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aims to compare the potential of whole-body silicon photomultiplier positron emission tomography/computed tomography (WB SiPM PET/CT) in the prone position with dynamic magnetic resonance imaging (MRI) in determining the extent of breast cancer.

METHODS

This retrospective study included 77 patients with 84 breast cancers who underwent both PET/CT and MRI, excluding those who received neoadjuvant chemotherapy. Four tumour thresholds for 18F-fluorodeoxyglucose uptake were defined based on the mean standardised uptake value (SUVmean) and standard deviation (SD) of normal breast tissue: SUVmean+2SD, SUVmean+3SD, 1.5SUVmean+2SD, and 1.5SUVmean+3SD. Semiautomatic measurements of tumour size for each threshold and MRI were compared against pathological tumour size and analysed by menopausal status and Ki-67 expression.

RESULTS

PET/CT failed to visualise two lesions. No significant differences in the image-to-pathological tumour size ratio were observed between MRI and the 1.5SUVmean+2SD. All MRI and SUV threshold measurements exhibited strong correlations with pathological size. The 1.5SUVmean+2SD demonstrated the highest pathological concordance rate, comparable to MRI. Subgroup analysis revealed that the 1.5SUVmean+2SD was superior for premenopausal patients (60.6%, p < 0.05), while MRI excelled in postmenopausal patients (61.2%). Both 1.5SUVmean+2SD and MRI achieved the highest concordance rates (62.2%) in the high-Ki-67 group.

CONCLUSION

The 1.5SUVmean+2SD of prone WB SiPM PET/CT offers a diagnostic performance equivalent to MRI for assessing breast cancer extent, particularly in premenopausal patients, while MRI remains optimal for postmenopausal patients. Both modalities are also highly effective in high Ki-67 tumours.

ADVANCES IN KNOWLEDGE: These findings highlight the potential of high-resolution semiconductor PET/CT for assessing breast cancer extent.

Для цитирования: Miyamoto Akina, Yoshizako Takeshi, Kuroda Hiroyuki, Yoshida Rika, Yamamoto Nobuko, Kaji Yasushi. Utility of High-Resolution Semiconductor Positron Emission Tomography/Computed Tomography in the Assessment of Breast Cancer Extent: Comparison with Magnetic Resonance Imaging.. The British journal of radiology. 2026. DOI: 10.1093/bjr/tqag157.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.