Weinreich David M, Sivapalasingam Sumathi, Norton Thomas, Ali Shazia, Gao Haitao, Bhore Rafia, Musser Bret J, Soo Yuhwen, Rofail Diana, Im Joseph, Perry Christina, Pan Cynthia, Hosain Romana, Mahmood Adnan, Davis John D, Turner Kenneth C, Hooper Andrea T, Hamilton Jennifer D, Baum Alina, Kyratsous Christos A, Kim Yunji, Cook Amanda, Kampman Wendy, Kohli Anita, Sachdeva Yessica, Graber Ximena, Kowal Bari, DiCioccio Thomas, Stahl Neil, Lipsich Leah, Braunstein Ned, Herman Gary, Yancopoulos George D, Trial Investigators

Клиническое исследование I фазыКлиническое исследование II фазыСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Recent data suggest that complications and death from coronavirus disease 2019 (Covid-19) may be related to high viral loads.

METHODS

In this ongoing, double-blind, phase 1-3 trial involving nonhospitalized patients with Covid-19, we investigated two fully human, neutralizing monoclonal antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein, used in a combined cocktail (REGN-COV2) to reduce the risk of the emergence of treatment-resistant mutant virus. Patients were randomly assigned (1:1:1) to receive placebo, 2.4 g of REGN-COV2, or 8.0 g of REGN-COV2 and were prospectively characterized at baseline for endogenous immune response against SARS-CoV-2 (serum antibody-positive or serum antibody-negative). Key end points included the time-weighted average change in viral load from baseline (day 1) through day 7 and the percentage of patients with at least one Covid-19-related medically attended visit through day 29. Safety was assessed in all patients.

RESULTS

Data from 275 patients are reported. The least-squares mean difference (combined REGN-COV2 dose groups vs. placebo group) in the time-weighted average change in viral load from day 1 through day 7 was -0.56 log10 copies per milliliter (95% confidence interval [CI], -1.02 to -0.11) among patients who were serum antibody-negative at baseline and -0.41 log10 copies per milliliter (95% CI, -0.71 to -0.10) in the overall trial population. In the overall trial population, 6% of the patients in the placebo group and 3% of the patients in the combined REGN-COV2 dose groups reported at least one medically attended visit; among patients who were serum antibody-negative at baseline, the corresponding percentages were 15% and 6% (difference, -9 percentage points; 95% CI, -29 to 11). The percentages of patients with hypersensitivity reactions, infusion-related reactions, and other adverse events were similar in the combined REGN-COV2 dose groups and the placebo group.

CONCLUSIONS

In this interim analysis, the REGN-COV2 antibody cocktail reduced viral load, with a greater effect in patients whose immune response had not yet been initiated or who had a high viral load at baseline. Safety outcomes were similar in the combined REGN-COV2 dose groups and the placebo group. (Funded by Regeneron Pharmaceuticals and the Biomedical and Advanced Research and Development Authority of the Department of Health and Human Services; ClinicalTrials.gov number, NCT04425629.).

Для цитирования: Weinreich David M, Sivapalasingam Sumathi, Norton Thomas, Ali Shazia, Gao Haitao, Bhore Rafia, Musser Bret J, Soo Yuhwen, Rofail Diana, Im Joseph, Perry Christina, Pan Cynthia, Hosain Romana, Mahmood Adnan, Davis John D, Turner Kenneth C, Hooper Andrea T, Hamilton Jennifer D, Baum Alina, Kyratsous Christos A, Kim Yunji, Cook Amanda, Kampman Wendy, Kohli Anita, Sachdeva Yessica, Graber Ximena, Kowal Bari, DiCioccio Thomas, Stahl Neil, Lipsich Leah, Braunstein Ned, Herman Gary, Yancopoulos George D, Trial Investigators. REGN-COV2, a Neutralizing Antibody Cocktail, in Outpatients with Covid-19.. The New England journal of medicine. 2020. DOI: 10.1056/nejmoa2035002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.