MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/archdischild-2018-315624

Медицинская библиотека · Archives of disease in childhood. Fetal and neonatal edition · 2018

Characterisation of neonatal seizures and their treatment using continuous EEG monitoring: a multicentre experience.

Rennie Janet M, de Vries Linda S, Blennow Mats, Foran Adrienne, Shah Divyen K, Livingstone Vicki, van Huffelen Alexander C, Mathieson Sean R, Pavlidis Elena, Weeke Lauren C, Toet Mona C, Finder Mikael, Pinnamaneni Raga Mallika, Murray Deirdre M, Ryan Anthony C, Marnane William P, Boylan Geraldine B

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The aim of this multicentre study was to describe detailed characteristics of electrographic seizures in a cohort of neonates monitored with multichannel continuous electroencephalography (cEEG) in 6 European centres.

METHODS

Neonates of at least 36 weeks of gestation who required cEEG monitoring for clinical concerns were eligible, and were enrolled prospectively over 2 years from June 2013. Additional retrospective data were available from two centres for January 2011 to February 2014. Clinical data and EEGs were reviewed by expert neurophysiologists through a central server.

RESULTS

Of 214 neonates who had recordings suitable for analysis, EEG seizures were confirmed in 75 (35%). The most common cause was hypoxic-ischaemic encephalopathy (44/75, 59%), followed by metabolic/genetic disorders (16/75, 21%) and stroke (10/75, 13%). The median number of seizures was 24 (IQR 9-51), and the median maximum hourly seizure burden in minutes per hour (MSB) was 21 min (IQR 11-32), with 21 (28%) having status epilepticus defined as MSB>30 min/hour. MSB developed later in neonates with a metabolic/genetic disorder. Over half (112/214, 52%) of the neonates were given at least one antiepileptic drug (AED) and both overtreatment and undertreatment was evident. When EEG monitoring was ongoing, 27 neonates (19%) with no electrographic seizures received AEDs. Fourteen neonates (19%) who did have electrographic seizures during cEEG monitoring did not receive an AED.

CONCLUSIONS

Our results show that even with access to cEEG monitoring, neonatal seizures are frequent, difficult to recognise and difficult to treat.

OBERSERVATION STUDY NUMBER: NCT02160171.

Для цитирования: Rennie Janet M, de Vries Linda S, Blennow Mats, Foran Adrienne, Shah Divyen K, Livingstone Vicki, van Huffelen Alexander C, Mathieson Sean R, Pavlidis Elena, Weeke Lauren C, Toet Mona C, Finder Mikael, Pinnamaneni Raga Mallika, Murray Deirdre M, Ryan Anthony C, Marnane William P, Boylan Geraldine B. Characterisation of neonatal seizures and their treatment using continuous EEG monitoring: a multicentre experience.. Archives of disease in childhood. Fetal and neonatal edition. 2018. DOI: 10.1136/archdischild-2018-315624.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.