MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1542-474x.2009.00292.x

Медицинская библиотека · Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2009

The measurement of the QT and QTc on the neonatal and infant electrocardiogram: a comprehensive reliability assessment.

Gow Robert M, Ewald Benjamin, Lai Lillian, Gardin Letizia, Lougheed Jane

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

An electrocardiogram has been proposed to screen for prolonged QT interval that may predispose infants to sudden death in the first year of life. Understanding the reliability of QT interval measurement will inform the design of a screening program.

METHODS

Three pediatric cardiologists measured the QT/RR intervals on 60 infant electrocardiograms (median age 46 days), from leads II, V5 and V6 on three separate occasions, 7 days apart, according to a standard protocol. The QTc was corrected by Bazett's (QTcB), Fridericia's (QT(CFrid)), and Hodges' (QTcH) formulae. Intraobserver and interobserver reliability were assessed by intraclass correlation coefficients (ICC), limits of agreement and repeatability coefficients for single, average of two and average of three measures. Agreement for QTc prolongation (> 440 msec) was assessed by kappa coefficients.

RESULTS

QT interval intraobserver ICC was 0.86 and repeatability coefficient was 25.9 msec; interobserver ICC increased from 0.88 for single observations to 0.94 for the average of 3 measurements and repeatability coefficients decreased from 22.5 to 16.7 msec. For QTcB, intraobserver ICC was 0.67, and repeatability was 39.6 msec. Best interobserver reliability for QTcB was for the average of three measurements (ICC 0.83, reproducibility coefficient 25.8 msec), with further improvement for QTcH (ICC 0.92, reproducibility coefficient 16.69 msec). Maximum interobserver kappa for prolonged QTc was 0.77. Misclassification around specific cut points occurs because of the repeatability coefficients.

CONCLUSIONS

Uncorrected QT measures are more reliable than QTcB and QT(CFrid). An average of three independent measures provides the most reliable QT and QTc measurements, with QTcH better than QTcB.

Для цитирования: Gow Robert M, Ewald Benjamin, Lai Lillian, Gardin Letizia, Lougheed Jane. The measurement of the QT and QTc on the neonatal and infant electrocardiogram: a comprehensive reliability assessment.. Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc. 2009. DOI: 10.1111/j.1542-474x.2009.00292.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.