MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7150/ijms.42593

Медицинская библиотека · International journal of medical sciences · 2020

Feasibility of the Figure-of-8-Suture as Venous Closure in Interventional Electrophysiology: One Strategy for All?

Jensen Christoph J, Schnur Miriam, Lask Sebastian, Attanasio Philipp, Gotzmann Michal, Kara Kaffer, Hanefeld Christoph, Mügge Andreas, Wutzler Alexander

СтатьяПеревод в очереди

Аннотация

Background

Venous vascular access with higher sheath size is common in interventional electrophysiology. In contrast to arterial vascular access, no dedicated closure devices exist for closure after venous access with higher sheath sizes. The Figure-of-8-Suture, an easy to apply suture, may be as a feasible approach for closure venous puncture. Our aim was to evaluate the feasibility of closure of femoral venous access.

Methods

From November 2016 to February 2018, patients undergoing electrophysiological procedures, closure of left atrial appendage or patent foramen ovale were included. Until May 2017, manual compression was performed to achieve haemostasis at venous access site (control group). From May 2017, patients were treated with a Figure-of-8-Suture (treatment group, Figure 1). Turnaround time and incidence of vascular complications were compared between the two groups.

Results

In total, 290 patients were included, 132 in the control group and 158 in the Figure-of-8-Suture group. Hemostasis after sheath removal was achieved in 100% of the cases in the control group by manual compression and in 98.7% of the cases with the Figure-of-8-Suture (p=0.2). Vascular complications were more common in the control group (6.8 vs. 1.3 %, p=0.01). Turnaround time was significantly lower in the Figure-of-8-Suture group (58.6 ± 14 vs. 77 ± 33.9 min, p=0.004). In a sub-analysis in obese patients with body mass index (BMI) ≥30 kg/m2 (Figure-of-8 n=45, controls n=35), vascular complications were significantly more common in the control group (9.4 vs 0%, p=0.045).

Conclusion

The Figure-of-8-Suture is an easy-to-apply, effective approach for venous closure after electrophysiological procedures.

Для цитирования: Jensen Christoph J, Schnur Miriam, Lask Sebastian, Attanasio Philipp, Gotzmann Michal, Kara Kaffer, Hanefeld Christoph, Mügge Andreas, Wutzler Alexander. Feasibility of the Figure-of-8-Suture as Venous Closure in Interventional Electrophysiology: One Strategy for All?. International journal of medical sciences. 2020. DOI: 10.7150/ijms.42593.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.