MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17219/dmp/163128

Медицинская библиотека · Dental and medical problems · 2026

Effect of the contamination and cleaning methods on the tensile bond strength of the polyetheretherketone restorative material cemented with dual-cure resin cement.

Ibrahim Iman Moheb, Sabet Ahmed Ezzat, Wahsh Marwa, Ahmed Fatma Adel Mohamed

СтатьяПеревод в очереди

Аннотация

BACKGROUND

These days, computer-aided design/computer-aided manufacturing (CAD/CAM) resinbased materials are being used daily in clinical practice for restorations in prosthetic dentistry. In comparison with ceramic materials, they are characterized by better stress distribution and decreased abrasion of the enamel of the opposing teeth. Consequently, they have been applied as alternative materials to ceramics in various dental restorations.

OBJECTIVES

The contamination of the indirect restorative material, which occurs at the clinical and dental laboratory stages, might deteriorate the bonding strength. The ideal surface treatment of the novel polyetheretherketone (PEEK) material for decontamination is yet unknown. The present study was conducted to evaluate the tensile bond strength (TBS) between PEEK and dual-cure self-adhesive resin cement, and determine the effect of contaminants, like temporary cement, artificial saliva and a fit checker, as well as the cleaning methods, like ultrasonic cleaning, phosphoric acid etching and universal cleaning paste (Ivoclean), on the bond.

MATERIAL AND

METHODS

Eighty PEEK disks were milled, having the final dimensions of 12 mm × 4 mm. The specimens were air-abraded with 50-micrometer aluminum oxide particles at a pressure of 2.8 bar for 15 s at a fixed distance of 10 mm, and then divided into 4 groups according to the contaminant used: temporary cement; artificial saliva; a fit checker; and a control group with no contamination. Furthermore, the first 3 groups were subsequently subdivided into 3 subgroups each according to the cleaning method applied: ultrasonic cleaning; phosphoric acid etching; and universal cleaning paste Ivoclean. The bonding of the specimens was done using dual-cure self-adhesive resin cement. The TBS of the different groups and subgroups was then measured at a crosshead speed of 2 mm/min in a universal testing machine (UTM), using a special test configuration.

RESULTS

There was a significant interaction between both tested variables (the contamination and cleaning methods) (p < 0.001). The samples contaminated with artificial saliva showed a significantly higher TBS value than the samples subjected to other contaminants (p = 0.005). For the samples contaminated with temporary cement and a fit checker, there were significant differences between the different cleaning methods, with ultrasonic cleaning providing the highest TBS values, followed by phosphoric acid etching, and finally Ivoclean (p < 0.001).

CONCLUSIONS

Under the conditions of the present study, temporary cement and a fit checker adversely affected the TBS of PEEK, and ultrasonic cleaning was most effective for decontamination.

Для цитирования: Ibrahim Iman Moheb, Sabet Ahmed Ezzat, Wahsh Marwa, Ahmed Fatma Adel Mohamed. Effect of the contamination and cleaning methods on the tensile bond strength of the polyetheretherketone restorative material cemented with dual-cure resin cement.. Dental and medical problems. 2026. DOI: 10.17219/dmp/163128.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.