Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia · 2023
Total Arterial Revascularization: Evaluating the Length of the Radial Artery in a Composite Graft Configuration.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Shahinian Jasmin H, Lappiere Harry, Grau Juan, Glineur David
Аннотация
PURPOSE: Reimplanting the radial artery in the left internal thoracic artery as a composite graft allows total arterial revascularization (TAR) without aortic manipulation. The limitation of this strategy is the length of the radial artery required to reach distal right coronary artery (RCA) branches. Our analysis focuses on the feasibility of this strategy.
METHODS: A total of 169 patients underwent TAR using the radial artery in a composite grafting configuration. Length of the radial artery, number of sequential anastomoses, heart size, target location, length of the arm, patient height, body surface area, and flow in the composite graft were prospectively collected.
RESULTS: The mean length of the radial artery was 18.02 cm. Patients with a mean length of the radial artery of 15.9 cm needed an extension of the radial artery with another conduit to reach the RCA distal branches. When T-configuration is used, the length of the radial artery should be 0.53 cm per sequential anastomosis to reach the RCA distal branches.
CONCLUSIONS: Our study shows that an average length of 18.02 cm of radial artery is needed to reach targets on the RCA distal branches in composite grafting. In T-configuration, we need 0.53 cm more length per anastomosis to achieve TAR.
METHODS: A total of 169 patients underwent TAR using the radial artery in a composite grafting configuration. Length of the radial artery, number of sequential anastomoses, heart size, target location, length of the arm, patient height, body surface area, and flow in the composite graft were prospectively collected.
RESULTS: The mean length of the radial artery was 18.02 cm. Patients with a mean length of the radial artery of 15.9 cm needed an extension of the radial artery with another conduit to reach the RCA distal branches. When T-configuration is used, the length of the radial artery should be 0.53 cm per sequential anastomosis to reach the RCA distal branches.
CONCLUSIONS: Our study shows that an average length of 18.02 cm of radial artery is needed to reach targets on the RCA distal branches in composite grafting. In T-configuration, we need 0.53 cm more length per anastomosis to achieve TAR.