Eleven Years of Experience in the Treatment of Aortoiliac Aneurysm with the E-Liac Stent-Graft System.
Аннотация
Background
This study examines the use of the E-liac stent-graft system for the endovascular treatment of aortoiliac or isolated common iliac aneurysms.
Methods
Consecutive patients between January 2014 and December 2024 were included. Data on patient characteristics, clinical presentation, lesion features, procedural aspects, and follow-up outcomes were collected and examined. Complications during the perioperative period and subsequent reinterventions were also documented.
Results
A total of 81 patients met the inclusion criteria (65 men, 80.2%, median age 71.2 ± 11.43 (range 61-86 years). Technical success was achieved in all cases. A total of 97 internal iliac arteries were revascularized; in 54 cases (66.7%), the endovascular technique was EVAR + unilateral iliac branch device (IBD), in 16 cases (19.8%), it was EVAR + bilateral IBDs, and unilateral isolated IBD was conducted in 11 (13.6%) patients. The median patient follow-up time was 64.7 months (range 1-120). During follow-up, the mortality rate was 22.2%, with an iliac branch patency of 90.1%. Buttock claudication was observed in five (6.2%) patients and nerve ischemia in one (1.2%). One type I endoleak (1.2%) occurred following endovascular treatment of an isolated common iliac artery aneurysm, and three type II endoleaks (3.7%) were observed; none of them were associated with aneurysm sac enlargement. Three type III endoleaks (3.7%) occurred due to disconnection of the iliac branch from the extension of the concomitant EVAR.
Conclusions
This long-term study, with 11 years of follow-up, reports outcomes with the E-liac stent-graft for the treatment of aorto-iliac or iliac aneurysms and demonstrates that it can be safely applied with low mortality and reintervention rates, and high patency rates.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.