MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2019.01.021

Медицинская библиотека · Journal of biomechanics · 2019

Myocardial bridging and endothelial dysfunction - Computational fluid dynamics study.

Javadzadegan Ashkan, Moshfegh Abouzar, Qian Yi, Kritharides Leonard, Yong Andy S C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Myocardial bridging (MB) is associated with endothelial dysfunction in patients with angina and non-obstructive coronary artery disease. This study aims to determine if there is a link between abnormal blood flow patterns and endothelial dysfunction in patients with MB. Ten patients with MB in their left anterior descending (LAD) artery were selected, 5 of whom had endothelial dysfunction and 5 had no endothelial dysfunction based on their response to acetylcholine. Similarly, 10 patients without MB in their LAD, 5 of whom had endothelial dysfunction and 5 of whom had no endothelial dysfunction, were studied as a control group. Transient computational fluid dynamics simulations were performed to derive wall shear stress (WSS) over the entire vessel including proximal, middle and distal segments. Patients with MB and endothelial dysfunction had lower WSS in the proximal LAD and greater WSS in the mid-LAD than patients with MB but without endothelial dysfunction. When comparing patients with endothelial dysfunction, those with MB had significantly lower shear stress in the proximal LAD (0.32 ± 0.14 Pa (with MB) vs 0.71 ± 0.38 Pa (without MB), p = 0.01) and greater shear stress in the mid-LAD (2.81 ± 1.20 Pa (with MB) vs 1.66 ± 0.31 Pa (without MB), p = 0.014) than patients without MB. Our findings demonstrated that the presence of MB significantly contributes to low WSS and endothelial dysfunction relationship.

Для цитирования: Javadzadegan Ashkan, Moshfegh Abouzar, Qian Yi, Kritharides Leonard, Yong Andy S C. Myocardial bridging and endothelial dysfunction - Computational fluid dynamics study.. Journal of biomechanics. 2019. DOI: 10.1016/j.jbiomech.2019.01.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.