British journal of anaesthesia · 2026

Videolaryngoscopy and first-attempt tracheal intubation success in neonates and infants: a retrospective cohort study using the Japan Pediatric Difficult Airway in Anesthesia (J-PEDIA) registry.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ukiya Tomoharu, Watanabe Fumio, Okuyama Megumi, Kobayashi Yasuma, Kaiho Yu, Imaizumi Takahiro, Kojima Taiki, J-PEDIA collaborators

Аннотация

BACKGROUND: First-attempt tracheal intubation success is critical in neonates and infants. Although videolaryngoscopy (VL) is recommended for neonatal and infant intubation, uncertainty remains regarding its effectiveness in real-world practice. We evaluated the association between use of VL for the initial tracheal intubation attempt and first-attempt tracheal intubation success in neonates and infants using a multicentre airway registry.

METHODS: This retrospective cohort study used data from the Japan Pediatric Difficult Airway in Anesthesia (J-PEDIA) registry, collected between June 2022 and February 2025. The primary outcome was first-attempt tracheal intubation success. Secondary outcomes included the percentage of glottic opening score, respiratory adverse events, and haemoglobin oxygen desaturation. Propensity score-based inverse probability of treatment weighting was applied to adjust for potential confounders.

RESULTS: Overall, 3250 encounters were analysed. After inverse probability of treatment weighting adjustment, VL was associated with a lower probability of first-attempt success than direct laryngoscopy (adjusted risk ratio 0.89, 95% confidence interval [CI] 0.83-0.96, P=0.001). VL was also associated with higher percentage of glottic opening scores (β 17.8, 95% CI 9.5-26.1, P<0.001), but increased risk of desaturation (adjusted risk ratio 2.18, 95% CI 1.57-2.79, P<0.001). The incidence of respiratory adverse events was similar between the groups (adjusted risk ratio -0.09, 95% CI -0.012 to 0.0097, P=0.86).

CONCLUSIONS: VL use was associated with lower first-attempt tracheal intubation success and a higher risk of desaturation compared with direct laryngoscopy. These findings suggest an efficacy-effectiveness gap in non-standardised real-world practice. Structured VL implementation and targeted training might be required to translate improved visualisation into successful first-attempt tracheal intubation.

CLINICAL TRIAL REGISTRATION: jRCT; registration number: 1040250033.