INTRODUCTION

The acquisition of digital impressions has become an integral part of clinical dentistry. The purpose of the present clinical simulation study was to evaluate the accuracy of digital impressions for maxillary full-arch implant-supported prostheses using two modern intraoral scanners with different acquisition technologies.

MATERIAL AND

METHODS

Two models of edentulous maxilla, with six implants at positions #16,14,12,22,24,26 (FDI World Dental Federation System, ISO 3950) or #3,5,7,10,12,14 (Universal Numbering system) were digitally designed, and 3D-printed in resin material (Asiga DentaMODEL, Australia). In the first scenario, all implants were parallelized, while in the second, implants #12/#7 and #22/#10 had a 20° angulation buccally, while implants #16/#3 and #26/#14 20° angulation distally. The models were scanned with two different intraoral scanners, Trios3 (3Shape, Denmark) and CS3600 (Carestream Dental, USA). Linear (x, y, z axes-top point) and angular deviations (x, y, z axes-Δφ) were assessed. Statistical analysis was performed using Kolmogorov-Smirnov tests (significance at p < 0.05).

RESULTS

Implant angulation showed a significant impact on accuracy, while the two scanners showed statistically significant differences. CS3600 demonstrated superior trueness, while Trios3 superior precision in both clinical scenarios. In the first clinical scenario a predominant occurrence of angular deviations was observed, while in the second scenario both angular and linear deviations were recorded. Scan body position also influenced scanning outcomes, with the last scan body captured demonstrating higher deviations.

CONCLUSION

Both scanners provided acceptable accuracy in the acquisition of digital impressions. Implant angulation and scan body position significantly affected trueness and precision. Clinicians should carefully consider implant angulations in full-arch implant restorations, as well as the scanning protocol.

Для цитирования: Vasileiadi Georgia, Ximinis Evangelos, Sarafidou Katia, Slini Theodora, Gogomitros Fotis, Athanasiadis George Andreas, Naka Olga, Tsouknidas Alexandros, Bakopoulou Athina, Kokoti Maria. The Effect of Angulation and Scan Body Position on Scans for Implant-Treated Edentulism: A Clinical Simulation Study.. Clinical implant dentistry and related research. 2025. DOI: 10.1111/cid.70001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.