MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0090226

Медицинская библиотека · PloS one · 2014

Rapid point-of-care breath test for biomarkers of breast cancer and abnormal mammograms.

Phillips Michael, Beatty J David, Cataneo Renee N, Huston Jan, Kaplan Peter D, Lalisang Roy I, Lambin Philippe, Lobbes Marc B I, Mundada Mayur, Pappas Nadine, Patel Urvish

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands.

METHODS

244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure.

RESULTS

Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO).

CONCLUSIONS

A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity.

Для цитирования: Phillips Michael, Beatty J David, Cataneo Renee N, Huston Jan, Kaplan Peter D, Lalisang Roy I, Lambin Philippe, Lobbes Marc B I, Mundada Mayur, Pappas Nadine, Patel Urvish. Rapid point-of-care breath test for biomarkers of breast cancer and abnormal mammograms.. PloS one. 2014. DOI: 10.1371/journal.pone.0090226.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.