Penile duplex pharmaco-ultrasonography revisited: revalidation of the parameters of the cavernous arterial response.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Speel T G W, van Langen H, Wijkstra H, Meuleman E J H
Аннотация
PURPOSE: We revalidate parameters of the cavernous arterial response (peak systolic blood flow velocity) and acceleration time using penile duplex pharmaco-ultrasonography.
MATERIALS AND METHODS: Blood flow velocity in the cavernous artery following pharmaco-stimulation was determined with duplex ultrasonography in 106 patients with erectile dysfunction. Intima media thickness of the common carotid artery, a valid index for atherosclerosis and clinical diagnosis based on a comprehensive evaluation were used as references. The clinical diagnosis was used to determine cutoff values. For the statistical analysis, Pearson correlation and ROC curves were used.
RESULTS: When correlating peak systolic velocity and acceleration time to intima media thickness, acceleration time (r = 0.51, p <0.01) was the most valid parameter to detect cavernous atherosclerotic pathology (peak systolic velocity r = -0.18, p = 0.12). This finding was confirmed by a comparison of both parameters to the clinical diagnosis. AUC was 0.59, 95% CI 0.49-0.69 for peak systolic velocity and 0.72 (95% CI 0.62-0.80 for acceleration time). The cutoff point for acceleration time to discriminate between atherosclerotic and nonatherosclerotic erectile dysfunction was determined at acceleration time 100 milliseconds or greater. Sensitivity was 66% and specificity was 71%.
CONCLUSIONS: The results of this study show that acceleration time has more power than peak systolic velocity to diagnose atherosclerotic erectile dysfunction.
MATERIALS AND METHODS: Blood flow velocity in the cavernous artery following pharmaco-stimulation was determined with duplex ultrasonography in 106 patients with erectile dysfunction. Intima media thickness of the common carotid artery, a valid index for atherosclerosis and clinical diagnosis based on a comprehensive evaluation were used as references. The clinical diagnosis was used to determine cutoff values. For the statistical analysis, Pearson correlation and ROC curves were used.
RESULTS: When correlating peak systolic velocity and acceleration time to intima media thickness, acceleration time (r = 0.51, p <0.01) was the most valid parameter to detect cavernous atherosclerotic pathology (peak systolic velocity r = -0.18, p = 0.12). This finding was confirmed by a comparison of both parameters to the clinical diagnosis. AUC was 0.59, 95% CI 0.49-0.69 for peak systolic velocity and 0.72 (95% CI 0.62-0.80 for acceleration time). The cutoff point for acceleration time to discriminate between atherosclerotic and nonatherosclerotic erectile dysfunction was determined at acceleration time 100 milliseconds or greater. Sensitivity was 66% and specificity was 71%.
CONCLUSIONS: The results of this study show that acceleration time has more power than peak systolic velocity to diagnose atherosclerotic erectile dysfunction.