MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.14532

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2019

The evaluation of right ventricular systolic function in patients with repaired Tetralogy of Fallot by conventional echocardiographic methods and speckle tracking echocardiography: Compared with the gold standard cardiac mangenetic resonance.

Kavurt Ahmet Vedat, Paç Feyza Ayşenur, Koca Serhat, Mutlu Mıhçıoğlu Ajda, Yiğit Hasan

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Right ventricular (RV) function is one of the important prognostic factors in patients with repaired Tetralogy of Fallot (TOF). We aimed to assess RV function by conventional echocardiography and two-dimensional speckle tracking echocardiography (2D-STE) in patients with repaired TOF.

METHODS

Twenty-seven (male 17) adolescents and young adult patients (mean age 22.7 ± 6.7 years) operated on for TOF and age- and gender-matched healthy controls were included. RV systolic function in both groups were evaluated by fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE), RV myocardial performance index (RVMPI) and tricuspid annular peak systolic velocity by pulsed tissue Doppler (tricuspid S'), and also RV global longitudinal strain (RV GLS) obtained from STE. These results were compared with RV ejection fraction (RVEF) measured by cardiac magnetic resonance imaging (CMRI) performed within 3 months in patient group.

RESULTS

Systolic RVGLS values were significantly lower in patients compared to controls (-17.4 ± 3.1% vs -25.6 ± 3%). Among the echocardiographic parameters, RVGLS had the best correlation with RV EF derived from CMRI (r: -.6). By receiver operating characteristics analysis (ROC), an RV GLS cutoff value of -17.4% had 75% sensitivity and 68.4% specificity in identifying RVEF <45% with an area under curve 0.743 (P < .05). The intra- and inter-observer agreement for RV GLS was excellent.

CONCLUSION

RVGLS is an easy, effective, feasible, and reproducible tool in the evaluation of RV systolic function. So, RVGLS measurement by STE may be one of the routine echocardiographic parameters in the evaluation of RV systolic function in patients with repaired TOF.

Для цитирования: Kavurt Ahmet Vedat, Paç Feyza Ayşenur, Koca Serhat, Mutlu Mıhçıoğlu Ajda, Yiğit Hasan. The evaluation of right ventricular systolic function in patients with repaired Tetralogy of Fallot by conventional echocardiographic methods and speckle tracking echocardiography: Compared with the gold standard cardiac mangenetic resonance.. Echocardiography (Mount Kisco, N.Y.). 2019. DOI: 10.1111/echo.14532.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.