MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-90645-5

Медицинская библиотека · Scientific reports · 2025

3D quantification of metal-induced geometric distortions in MRI.

Li Hao, Özen Ali C, Juerchott Alexander, Breckwoldt Michael, Jesser Jessica, Vollherbst Dominik F, Schwarz Daniel, Bendszus Martin, Heiland Sabine, Hilgenfeld Tim

СтатьяПеревод в очереди

Аннотация

The increasing number of patients with metal implants raises concerns about metal-induced geometric distortions (MD) in MR-guided treatments. This study proposes a method for three-dimensional quantification of MD and evaluates its accuracy and reliability. A 3D lattice phantom was designed and measured with two sequences (VIBE and SPACE) and two implants (crown-supported-dental-implant and stainless-steel-bracket). Automated detection of displacement of 9360 crossing points caused by MD was performed. Distortion-quantification accuracy was improved by correcting for noise-induced error (NE), related to different signal-to-noise ratios (SNR), and implant-related signal loss and pile-up artifact volumes (SLPUA). The method's accuracy was validated against computed tomography. Results showed high reliability, with an excellent intraclass correlation coefficient (≥ 0.99) and low mean residual errors in all directions (2.6%/1.6%/1.8% of voxel size in X/Y/Z direction). SNR/SLPUA volumes were significant confounders (p-value ≤ 0.001) when comparing different sequences/implants, but corrections significantly reduced their impacts (p-value ≤ 0.001). This method enables accurate 3D MD quantification and fair comparison across different sequences/implants. By optimizing MRI protocols for MD minimization and defining implant-specific MD profiles for patient data correction, it may help improve spatial accuracy in MRI-guided treatments in the future.

Для цитирования: Li Hao, Özen Ali C, Juerchott Alexander, Breckwoldt Michael, Jesser Jessica, Vollherbst Dominik F, Schwarz Daniel, Bendszus Martin, Heiland Sabine, Hilgenfeld Tim. 3D quantification of metal-induced geometric distortions in MRI.. Scientific reports. 2025. DOI: 10.1038/s41598-025-90645-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.