Evaluation of the ARK Diagnostics immunoassay for qualitative detection of xylazine in urine.

Kyle Patrick B, Mattiello Christopher J, Hua Albert, Toohey Joanne M, Korn Warren R, Saldana-Reed Alana, Stickle Douglas F

СтатьяПеревод в очереди

Аннотация

Xylazine exposure is common in some US cities, but a commercial assay for routine laboratory testing for xylazine is not currently available. We evaluated a pre-release version of the ARK Diagnostics immunoassay for qualitative detection of xylazine/4-hydroxyxylazine in urine. Studies were conducted using either the semi-quantitative assay application (A. Roche Cobas 503 analyzer) or the qualitative assay application (B. Beckman Coulter AU480 analyzer). Study specimens consisted of deidentified patient urine samples submitted for routine drugs-of-abuse testing. Measurements of xylazine (X) were performed by LC-MS-MS to obtain X-NEGATIVE (X <10 ng/mL) and X-POSITIVE (X ≥10 ng/mL). The semi-quantitative ARK assay was calibrated with a 10 ng/mL cutoff for ARK-POSITVE. For (A): among 74 X-POSITIVE samples, there was 1 ARK-NEGATIVE result (false-negative rate = 1.4%); among 78 X-NEGATIVE samples by LC-MS-MS, there were 0% ARK-POSITIVE results (false-positive rate = 0%). For (B), among 74 X-POSITIVE samples, there were 0 ARK-NEGATIVE results (false-negative rate = 0%); among 78 X-NEGATIVE samples there was 1 ARK-POSITIVE sample (false-positive rate = 1.3%). Common sources of interferences were investigated without evidence of interference. The ARK xylazine/4-OH-xylazine immunoassay was found to be suitable for routine use in screening patient urine samples for presence of xylazine >10 ng/mL.

Для цитирования: Kyle Patrick B, Mattiello Christopher J, Hua Albert, Toohey Joanne M, Korn Warren R, Saldana-Reed Alana, Stickle Douglas F. Evaluation of the ARK Diagnostics immunoassay for qualitative detection of xylazine in urine.. Journal of analytical toxicology. 2024. DOI: 10.1093/jat/bkae043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.