MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.16211

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2024

Prognostic benefits of His-Purkinje capture in physiological pacemakers for bradycardia.

Tan Eugene S J, Soh Rodney, Lee Jie-Ying, Boey Elaine, Chan Siew-Pang, Lim Toon Wei, Yeo Wee Tiong, Leong Kevin M W, Seow Swee-Chong, Kojodjojo Pipin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Clinical outcomes of long-term ventricular septal pacing (VSP) without His-Purkinje capture remain unknown. This study evaluated the differences in clinical outcomes between conduction system pacing (CSP), VSP, and right ventricular pacing (RVP).

METHODS

Consecutive patients with bradycardia indicated for pacing from 2016 to 2022 were prospectively followed for the clinical endpoints of heart failure (HF)-hospitalizations and all-cause mortality at 2 years. VSP was defined as septal pacing due to unsuccessful CSP implant or successful CSP followed by loss of His-Purkinje capture within 90 days.

RESULTS

Among 1016 patients (age 73.9 ± 11.2 years, 47% female, 48% atrioventricular block), 612 received RVP, 335 received CSP and 69 received VSP. Paced QRS duration was similar between VSP and RVP, but both significantly longer than CSP (p < .05). HF-hospitalizations occurred in 130 (13%) patients (CSP 7% vs. RVP 16% vs. VSP 13%, p = .001), and all-cause mortality in 143 (14%) patients (CSP 7% vs. RVP 19% vs. VSP 9%, p < .001). The association of pacing modality with clinical events was limited to those with ventricular pacing (Vp) > 20% (pinteraction < .05). Adjusting for clinical risk factors among patients with Vp > 20%, VSP (adjusted hazard ratio [AHR]: 4.74, 95% confidence interval [CI]: 1.57-14.36) and RVP (AHR: 3.08, 95% CI: 1.44-6.60) were associated with increased hazard of HF-hospitalizations, and RVP (2.52, 95% CI: 1.19-5.35) with increased mortality, compared to CSP. Clinical endpoints did not differ between VSP and RVP with Vp > 20%, or amongst groups with Vp < 20%.

CONCLUSION

Conduction system capture is associated with improved clinical outcomes. CSP should be preferred over VSP or RVP during pacing for bradycardia.

Для цитирования: Tan Eugene S J, Soh Rodney, Lee Jie-Ying, Boey Elaine, Chan Siew-Pang, Lim Toon Wei, Yeo Wee Tiong, Leong Kevin M W, Seow Swee-Chong, Kojodjojo Pipin. Prognostic benefits of His-Purkinje capture in physiological pacemakers for bradycardia.. Journal of cardiovascular electrophysiology. 2024. DOI: 10.1111/jce.16211.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.