Hoorntje Edgar T, Burns Charlotte, Marsili Luisa, Corden Ben, Parikh Victoria N, Te Meerman Gerard J, Gray Belinda, Adiyaman Ahmet, Bagnall Richard D, Barge-Schaapveld Daniela Q C M, van den Berg Maarten P, Bootsma Marianne, Bosman Laurens P, Correnti Gemma, Duflou Johan, Eppinga Ruben N, Fatkin Diane, Fietz Michael, Haan Eric, Jongbloed Jan D H, Hauer Arnaud D, Lam Lien, van Lint Freyja H M, Lota Amrit, Marcelis Carlo, McCarthy Hugh J, van Mil Anneke M, Oldenburg Rogier A, Pachter Nicholas, Planken R Nils, Reuter Chloe, Semsarian Christopher, van der Smagt Jasper J, Thompson Tina, Vohra Jitendra, Volders Paul G A, van Waning Jaap I, Whiffin Nicola, van den Wijngaard Arthur, Amin Ahmad S, Wilde Arthur A M, van Woerden Gijs, Yeates Laura, Zentner Dominica, Ashley Euan A, Wheeler Matthew T, Ware James S, van Tintelen J Peter, Ingles Jodie

ОбзорСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Truncating variants in desmoplakin (DSPtv) are an important cause of arrhythmogenic cardiomyopathy; however the genetic architecture and genotype-specific risk factors are incompletely understood. We evaluated phenotype, risk factors for ventricular arrhythmias, and underlying genetics of DSPtv cardiomyopathy.

METHODS

Individuals with DSPtv and any cardiac phenotype, and their gene-positive family members were included from multiple international centers. Clinical data and family history information were collected. Event-free survival from ventricular arrhythmia was assessed. Variant location was compared between cases and controls, and literature review of reported DSPtv performed.

RESULTS

There were 98 probands and 72 family members (mean age at diagnosis 43±8 years, 59% women) with a DSPtv, of which 146 were considered clinically affected. Ventricular arrhythmia (sudden cardiac arrest, sustained ventricular tachycardia, appropriate implantable cardioverter defibrillator therapy) occurred in 56 (33%) individuals. DSPtv location and proband status were independent risk factors for ventricular arrhythmia. Further, gene region was important with variants in cases (cohort n=98; Clinvar n=167) more likely to occur in the regions resulting in nonsense mediated decay of both major DSP isoforms, compared with n=124 genome aggregation database control variants (148 [83.6%] versus 29 [16.4%]; P<0.0001).

CONCLUSIONS

In the largest series of individuals with DSPtv, we demonstrate that variant location is a novel risk factor for ventricular arrhythmia, can inform variant interpretation, and provide critical insights to allow for precision-based clinical management.

Для цитирования: Hoorntje Edgar T, Burns Charlotte, Marsili Luisa, Corden Ben, Parikh Victoria N, Te Meerman Gerard J, Gray Belinda, Adiyaman Ahmet, Bagnall Richard D, Barge-Schaapveld Daniela Q C M, van den Berg Maarten P, Bootsma Marianne, Bosman Laurens P, Correnti Gemma, Duflou Johan, Eppinga Ruben N, Fatkin Diane, Fietz Michael, Haan Eric, Jongbloed Jan D H, Hauer Arnaud D, Lam Lien, van Lint Freyja H M, Lota Amrit, Marcelis Carlo, McCarthy Hugh J, van Mil Anneke M, Oldenburg Rogier A, Pachter Nicholas, Planken R Nils, Reuter Chloe, Semsarian Christopher, van der Smagt Jasper J, Thompson Tina, Vohra Jitendra, Volders Paul G A, van Waning Jaap I, Whiffin Nicola, van den Wijngaard Arthur, Amin Ahmad S, Wilde Arthur A M, van Woerden Gijs, Yeates Laura, Zentner Dominica, Ashley Euan A, Wheeler Matthew T, Ware James S, van Tintelen J Peter, Ingles Jodie. Variant Location Is a Novel Risk Factor for Individuals With Arrhythmogenic Cardiomyopathy Due to a Desmoplakin (DSP) Truncating Variant.. Circulation. Genomic and precision medicine. 2022. DOI: 10.1161/circgen.121.003672.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.