MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/uog.17337

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2017

Ultrasound and histological measurements of dividing membrane thickness in twin gestations.

Bracero L A, Huff C, Blitz M J, Plata M J, Seybold D J, Broce M

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To determine how prenatal ultrasound measurements of dividing membrane thickness correlate with postnatal histological measurements and chorionicity in twin gestations.

METHODS

This was a prospective, longitudinal cohort study of twin gestations. Dividing membrane thickness was measured by transabdominal ultrasound, with the insonation beam both parallel and perpendicular to the membrane, in the second or third trimester, depending on when care was established. Ultrasound examinations were performed every 4 weeks following initial assessment until delivery. Measurements of membrane thickness from the first ultrasound examination were compared with histological measurements after delivery.

RESULTS

A total of 45 twin pregnancies (32 dichorionic, 13 monochorionic) were included. Mean gestational age at initial ultrasound examination was 24.1 ± 7.3 weeks. Parallel ultrasound measurements of membrane thickness were 1.6 ± 0.8 mm for monochorionic and 2.5 ± 0.9 mm for dichorionic gestations (P = 0.001). Perpendicular ultrasound measurements were 1.6 ± 0.3 mm for monochorionic and 2.2 ± 0.8 mm for dichorionic gestations (P = 0.009). Inter- and intraobserver reliability of ultrasound measurements were 0.847 and 0.950, respectively. Parallel and perpendicular ultrasound measurements correlated better with each other (R = 0.807, P < 0.001) than with histological measurements of membrane thickness (Rparallel  = 0.538, P < 0.001; Rperpendicular  = 0.529, P < 0.001). Receiver-operating characteristics curve analyses to predict histological membrane thickness > 50th percentile resulted in an area under the curve (AUC) of 0.828 for parallel (P < 0.001) and 0.874 for perpendicular (P < 0.001) measurements with a cut-off value of 1.9 mm for both approaches. The AUCs for parallel and perpendicular measurements to predict dichorionicity were 0.892 (P < 0.001) and 0.823 (P < 0.001) with cut-off values of 1.9 and 1.8 mm, respectively.

CONCLUSION

Prenatal ultrasound measurement of twin dividing membrane thickness is positively correlated with postnatal histological measurement. Dichorionicity can be determined by a magnified dividing membrane thickness ≥ 1.9 mm. Measurements with the ultrasound beam parallel to the dividing membrane may be more accurate than perpendicular measurements. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

Для цитирования: Bracero L A, Huff C, Blitz M J, Plata M J, Seybold D J, Broce M. Ultrasound and histological measurements of dividing membrane thickness in twin gestations.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2017. DOI: 10.1002/uog.17337.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.