MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tmi.2024.3376668

Медицинская библиотека · IEEE transactions on medical imaging · 2024

3D Single Vessel Fractional Moving Blood Volume (3D-svFMBV): Fully Automated Tissue Perfusion Estimation Using Ultrasound.

Yin Yi, Clark Alys R, Collins Sally L

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Power Doppler ultrasound (PD-US) is the ideal modality to assess tissue perfusion as it is cheap, patient-friendly and does not require ionizing radiation. However, meaningful inter-patient comparison only occurs if differences in tissue-attenuation are corrected for. This can be done by standardizing the PD-US signal to a blood vessel assumed to have 100% vascularity. The original method to do this is called fractional moving blood volume (FMBV). We describe a novel, fully-automated method combining image processing, numerical modelling, and deep learning to estimate three-dimensional single vessel fractional moving blood volume (3D-svFMBV). We map the PD signals to a characteristic intensity profile within a single large vessel to define the standardization value at the high shear vessel margins. This removes the need for mathematical correction for background signal which can introduce error. The 3D-svFMBV was first tested on synthetic images generated using the characteristics of uterine artery and physiological ultrasound noise levels, demonstrating prediction of standardization value close to the theoretical ideal. Clinical utility was explored using 143 first-trimester placental ultrasound volumes. More biologically plausible perfusion estimates were obtained, showing improved prediction of pre-eclampsia compared with those generated with the semi-automated original 3D-FMBV technique. The proposed 3D-svFMBV method overcomes the limitations of the original technique to provide accurate and robust placental perfusion estimation. This not only has the potential to provide an early pregnancy screening tool but may also be used to assess perfusion of different organs and tumors.

Для цитирования: Yin Yi, Clark Alys R, Collins Sally L. 3D Single Vessel Fractional Moving Blood Volume (3D-svFMBV): Fully Automated Tissue Perfusion Estimation Using Ultrasound.. IEEE transactions on medical imaging. 2024. DOI: 10.1109/tmi.2024.3376668.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.