DOI 10.1097/j.jcrs.0000000000001575
Severe intraocular lens tilt after the Yamane technique.
Аннотация
PURPOSE: To evaluate CT Lucia 602 intraocular lenses implanted in cases lacking capsular support and explanted because of decentration/dislocation with subsequent pathological analysis. The main objectives were to (1) document the status of haptics and (2) verify the presence of the rotisserie effect.
SETTING
John A. Moran Eye Center, University of Utah, Salt Lake City, Utah.
DESIGN
Case series with clinicopathological correlation.
METHODS
13 explanted CT Lucia 602 lenses were included: 12 implanted by the Yamane technique and 1 that was iris-fixated. 4 lenses were explanted between October 2020 and February 2022. 9 lenses, explanted between November 2022 and February 2024, also exhibited severe optic tilt, leading to explantation. A chart review was performed to obtain clinical information from each case. Explanted lenses underwent gross and microscopic examination for haptic status and rotation, in the dry state (room temperature) and after hydration (body temperature).
RESULTS
Time between implantation and explantation was longer for lenses explanted before November 2022 (without severe tilt). Among the 26 haptics evaluated, 15 were deformed, 6 were broken, 2 were detached, and 3 were unremarkable. 4 haptics of Yamane lenses explanted between November 2022 and February 2024 showed free rotation within the optic insertion, after hydration at body temperature.
CONCLUSIONS
Anecdotal reports of the rotisserie effect of CT Lucia 602 lenses implanted by the Yamane technique appeared mostly during the second half of 2022 and suggested that affected lenses were from specific batches, which seems to be consistent with the findings of this study.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.