Quad-Band Terahertz Metasurface Flexible Biosensor for HCC Biomarker Detection Using a Multipeak Data Fusion Strategy.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Huang Jiehao, Wen Pin, Liu Jinyu, Zhan Kun, Zhou Song, Huang Xin, Wang Yuhao

Аннотация

Terahertz technology, with its label-free, nondestructive nature and unique fingerprint spectral characteristics for biomolecules, holds great promise for high-sensitivity detection of cancer biomarkers. However, conventional terahertz biosensors typically achieve sensing based on a single resonant peak, which inherently limits the sensitivity and detection precision. In this article, a flexible quad-band terahertz metasurface biosensor is proposed. The biosensor employs a mirrored double-F-shaped metallic unit cell, which generates four resonant peaks at 1.02, 2.27, 2.60, and 2.95 THz. Moreover, a multipeak data fusion strategy is proposed to jointly analyze the frequency shifts of the four resonant peaks, which can enhance the sensitivity and precision simultaneously. For verification, a biosensor prototype is fabricated on a polyethylene terephthalate substrate. Two kinds of cancer biomarkers alpha-fetoprotein and carcinoembryonic antigen related to hepatocellular carcinoma (HCC) are used as experimental samples. The results show that the detection sensitivities (35.4 and 31.1 GHz/lg (ng/mL)) obtained using the multipeak data fusion strategy based on cumulative frequency shifts are both higher than those measured from the four single peaks under the same concentration. The biosensor achieves a limit of detection as low as 1.00 ng/mL for both biomarkers. Furthermore, by fusing multipeak data through average frequency shift analysis, random noise is effectively suppressed, thereby reducing the relative standard deviation to less than 3% and significantly improving the linearity (R2 > 0.99). In comparison with conventional approaches, the proposed method exhibits heightened sensitivity and precision. Consequently, this research offers an effective solution for the early clinical diagnosis of cancer.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты