Serum Inhaled Corticosteroid Detection for Monitoring Adherence in Severe Asthma.

Alahmadi Fahad H, Keevil Brian, Elsey Lynn, George Kate, Niven Robert, Fowler Stephen J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Daily inhaled corticosteroids (ICSs) are fundamental to asthma management, but adherence is low.

OBJECTIVES

To investigate (1) whether LC-MS/MS could be used to detect ICSs in serum and (2) whether serum levels related to markers of disease severity.

METHODS

We collected blood samples over an 8-hour period from patients with severe asthma prescribed at least 1000 μg daily of beclomethasone dipropionate equivalent. Following baseline sampling, patients were observed taking their usual morning dose. Subsequent blood samples were obtained 1, 2, 4, and 8 hours postinhalation and analyzed by LC-MS/MS. Correlations between serum ICS levels and severity markers were investigated.

RESULTS

A total of 60 patients were recruited (41 females; 39 prescribed maintenance prednisolone; mean age, 49 ± 12 years; FEV1, 63 ± 20 %predicted). Eight hours postinhalation, all patients using budesonide (n = 10) and beclomethasone dipropionate (15), and all but 1 using fluticasone propionate (28), had detectable serum drug levels. Fluticasone furorate was detected in 2 patients (of 4), ciclesonide in none (of 7). Low adherence by repeat prescription records (<80%) was identified in 43%. Blood ICS levels correlated negatively with exacerbation rate, and (for fluticasone propionate only) positively with FEV1 %predicted.

CONCLUSIONS

Commonly used ICSs can be reliably detected in the blood at least 8 hours after dosing, and could therefore be used as a measure of adherence in severe asthma. Higher exacerbation rates and poorer lung function (for fluticasone propionate) were associated with lower blood levels.

Для цитирования: Alahmadi Fahad H, Keevil Brian, Elsey Lynn, George Kate, Niven Robert, Fowler Stephen J. Serum Inhaled Corticosteroid Detection for Monitoring Adherence in Severe Asthma.. The journal of allergy and clinical immunology. In practice. 2021. DOI: 10.1016/j.jaip.2021.05.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.