BACKGROUND

The use of mechanical circulatory support devices for high-risk percutaneous coronary intervention (PCI) has increased over the past decade despite limited data of benefit. We sought to examine the association between intravascular microaxial left ventricular assist device (LVAD) versus intra-aortic balloon pump use in patients without cardiogenic shock (CS) undergoing PCI.

METHODS AND

RESULTS

This retrospective study analyzed claims data from a large, insured population who underwent PCI without CS from April 1, 2016 to July 31, 2022. Using inverse probability treatment weighting, we assessed for the association between device type and clinical outcomes. The primary outcome was all-cause mortality. Secondary outcomes included stroke, bleeding, incident dialysis, repeat revascularization, and total health care costs during the index admission and at 30 days. We identified 2879 patients without CS who underwent PCI with either an intra-aortic balloon pump or microaxial LVAD. The mean±SD age was 68.2±12.5 years, and 27% (n=764) were women. After propensity weighting, intravascular LVAD use was not associated with a significant difference in either in-hospital (odds ratio [OR] 1.30 [95% CI, 0.88-1.91]; P=0.19) or 30-day mortality (OR, 1.19 [95% CI, 0.84-1.69]; P=0.33) compared with intra-aortic balloon pump use. Compared with those receiving an intra-aortic balloon pump, the mean total costs for the index admission ($96 716 versus $71 892; P<0.001) and at 30 days (+$16 671 [95% CI, $6639-$28 103]; P=0.001) were significantly higher in those receiving an intravascular LVAD. There was no significant association between device type and stroke, bleeding, incident dialysis, and repeat revascularization at any time point (all P>0.05).

CONCLUSIONS

In patients without CS undergoing PCI, intravascular LVAD use was associated with higher costs but not associated with lower mortality. Randomized data are needed to improve device selection for patients without CS undergoing PCI.

Для цитирования: Miller P Elliott, Gordon Aliza S, Liu Ying, Ahmad Tariq, Bromfield Samantha G, Girotra Saket, Davila Carlos D, Crawford Geoffrey, Whitney John, Desai Nihar R. Mechanical Circulatory Support in Patients Without Cardiogenic Shock Undergoing Percutaneous Coronary Intervention.. Journal of the American Heart Association. 2025. DOI: 10.1161/jaha.124.037424.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.