m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. A · 2026

Development and validation of a multiplexed LC-HRMS method for nine GLP-1 receptor agonists and its pharmaceutical application.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tong Lok-Hang, Leung King-Kwong, Hung Chi-Tat

Аннотация

A rapid, sensitive, and selective multiplexed liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method was developed and validated for the identification and quantitation of nine structurally diverse peptide-based glucagon-like peptide-1 receptor agonists (GLP-1 RAs): bofanglutide, ecnoglutide, exenatide, liraglutide, mazdutide, retatrutide, semaglutide, survodutide, and tirzepatide. These peptides represent single, dual, and triple receptor agonists, including four globally approved medications, two recently approved by China's National Medical Products Administration (NMPA), and three investigational drugs in Phase III clinical trials. Chromatographic separation was achieved on an ACQUITY Premier BEH C18 column (2.1 × 150 mm, 1.7 µm) at 50 °C using a multistep linear gradient with water and acetonitrile containing 0.1% difluoroacetic acid (DFA) and 0.5% dimethyl sulfoxide (DMSO) as mobile phases (flow rate 0.3 mL/min). The optimised method provided excellent resolution with baseline separation for most peptides within a 20-minute runtime. A key advantage of this work is the implementation of a dual strategy that combines high-resolution full-scan MS (HRMS) for accurate mass measurement with data-dependent HRMS/MS fragmentation for structural confirmation. Peptide identification adopted a top-down approach, achieving mass accuracy of 0.0-0.5 ppm and fragment ion coverage of 76-100%. The method showed good linearity (r² ≥ 0.995) over 4-235 ng/mL, with LODs of 0.44-2.06 ng/mL and LOQs of 8.29-11.74 ng/mL. It was successfully applied to marketed formulations of liraglutide, semaglutide, and tirzepatide using a simple dilute-and-shoot procedure, yielding mean recoveries of 113.7-118.4%. This LC-HRMS method offers superior selectivity and flexibility for analysing current and next-generation GLP-1 RAs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты