Fluid infusion into the pericardium resulting from accidental displacement of a subclavian venous cannula.

Kapoor Mukul C, Kumar Sameer, Gourishanker Ramesh

Клинический случайСтатьяПеревод в очереди

Аннотация

A patient for double valve replacement developed an unusual complication consequent to extra-vascular displacement of a port of a central venous catheter, placed through the right subclavian vein. The patient had an uneventful surgical course and the trachea extubated after routine mechanical ventilation. Patient developed excessive mediastinal drainage later, which was noticed to be watery in nature. The source of the drainage was found to be a port of the central venous catheter, draining extra-vascular into the subclavian vascular sheath and thereafter through the pericardium into the mediastinal drains.