MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtos.2023.09.010

Медицинская библиотека · The ocular surface · 2023

New insights into lacrimal gland anatomy using 7T MRI and electron microscopy: Relevance for lacrimal gland targeted therapies and bioengineering.

Singh Swati, Winter Zoltan, Necker Fabian, Bäuerle Tobias, Scholz Michael, Bräuer Lars, Paulsen Friedrich

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To study the tissue architecture, isthmus (connection between two lobes) of the lacrimal gland using preclinical 7T MRI in combination with histology and electron microscopy.

METHODS

Ten lacrimal glands from Caucasian body donors (mean age 78.7 years) were studied using 7T-MRI (N = 5; scanned at 75-μm intervals), histology, and electron microscopy (N = 5) and 3D cinematic rendering (CR) techniques.

RESULTS

3D CR images showed uniform-sized lobules (widest lobule diameter, 1.68 ± 0.19 mm in orbital lobe, 1.68 ± 0.17 mm in palpebral lobe) in both lobes, separated by septae (size, 0.29 ± 0.09 mm). The internal framework of the gland resembled a honeycoomb pattern. In CR and histology, the isthmus contained glandular acini, large blood vessels, nerves, and no more than two ducts having a tortuous course towards the conjunctival surface. On assigning a color display to the rendered lacrimal gland, all glands showed a blood vessel originating from the main lacrimal artery just 5 mm beyond the hilum and making it course to the palpebral lobe via isthmus. The distance between the conjunctiva and the central substance of the orbital and palpebral lobe was 9.4 ± 0.2 mm and 2.8 ± 0.7 mm, respectively. Electron microscopy of the palpebral lobe revealed compact subepithelial layer in the overlying conjunctiva, followed by loosely scattered collagen bundles that contained the gland lobules.

CONCLUSION

3D-CR can be used to study the lacrimal gland microstructure, help fabricate a 3D scaffold for lacrimal gland bioprinting, and serve as guide for transconjunctival lacrimal gland targeted therapies i.e., 2.9 & 9 mm long needle to reach the orbital and palpebral lobe center, respectively in normal-size glands.

Для цитирования: Singh Swati, Winter Zoltan, Necker Fabian, Bäuerle Tobias, Scholz Michael, Bräuer Lars, Paulsen Friedrich. New insights into lacrimal gland anatomy using 7T MRI and electron microscopy: Relevance for lacrimal gland targeted therapies and bioengineering.. The ocular surface. 2023. DOI: 10.1016/j.jtos.2023.09.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.