MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/thy.2011.0014

Медицинская библиотека · Thyroid : official journal of the American Thyroid Association · 2011

Immunocytochemistry with cytokeratin 19 and anti-human mesothelial cell antibody (HBME1) increases the diagnostic accuracy of thyroid fine-needle aspirations: preliminary report of 150 liquid-based fine-needle aspirations with histological control.

Cochand-Priollet Beatrix, Dahan Henri, Laloi-Michelin Marie, Polivka Marc, Saada Michele, Herman Philippe, Guillausseau Pierre-Jean, Hamzi Lounis, Poté Nicolas, Sarfati Emile, Wassef Michel, Combe Herve, Raulic-Raimond Danielle, Chedin Pierre, Medeau Virginie, Casanova Daniele, Kania Romain

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Thyroid nodules are relatively common (7% of the population) but are malignant in only 5%-10% of cases. Fine-needle aspiration (FNA) to detect cancer can have > 90% sensitivity but only 50%-65% specificity because of false-positive results, which necessitates surgical controls. We aimed to assess the diagnostic accuracy of immunocytochemistry (ICC) of thyroid FNA to improve its sensitivity and specificity.

METHODS

We prospectively collected 2038 thyroid FNAs, of which 1397 were FNA biopsies with liquid-based cytology (Thin-Prep-Hologic®). ICC with cytokeratin 19 and HBME1 antibodies (Dako® A/S) was used for all malignant cases and cases of atypical cells of undetermined significance (AUS), follicular neoplasm (FN), and nodules suspicious for malignancy-papillary thyroid carcinoma (SM-PTC) as well as some benign cases (abnormal features on radiography or benign on secondary FNA). ICC results were defined as "non-contributory," "favoring benign," "favoring malignant," or "indeterminate." Results for 150 cases were compared with histological controls for diagnostic accuracy.

RESULTS

Of these 150 cases ICC was helpful for benign or malignant triage of 48 cases of AUS, FN, and SM-PTC (42% of these lesions). Six (4%) ICC results were false positive (favoring malignant with benign histology) but none were false negative (favoring benign with malignant histology). Results for indeterminate cytological cases favored malignant or benign disease with sensitivity, specificity, and negative and positive predictive values of 100%, 85.2%, 100%, and 86.2%, respectively.

CONCLUSIONS

ICC of thyroid FNAs with cytokeratin 19 and HBME1 antibodies can reduce the false-positive and false-negative results of single morphological analyses. It can increase the sensitivity and specificity of diagnosis, thus improving diagnostic accuracy and reducing the need for surgical controls.

Для цитирования: Cochand-Priollet Beatrix, Dahan Henri, Laloi-Michelin Marie, Polivka Marc, Saada Michele, Herman Philippe, Guillausseau Pierre-Jean, Hamzi Lounis, Poté Nicolas, Sarfati Emile, Wassef Michel, Combe Herve, Raulic-Raimond Danielle, Chedin Pierre, Medeau Virginie, Casanova Daniele, Kania Romain. Immunocytochemistry with cytokeratin 19 and anti-human mesothelial cell antibody (HBME1) increases the diagnostic accuracy of thyroid fine-needle aspirations: preliminary report of 150 liquid-based fine-needle aspirations with histological control.. Thyroid : official journal of the American Thyroid Association. 2011. DOI: 10.1089/thy.2011.0014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.