MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6an00937a

Медицинская библиотека · The Analyst · 2026

Peptide-based digital ELISA with single-molecule arrays for ultrasensitive and specific endotoxin detection in clinical plasma and pharmaceutical products.

Li Junrong, Cao Kun, Yang Heqing, Dong Jicheng, Wang Quanwu, Hai Feng

СтатьяПеревод в очереди

Аннотация

Endotoxin detection is critical for the diagnosis and management of sepsis and for the safety evaluation of pharmaceutical products. Here, we report a peptide-based digital enzyme-linked immunosorbent assay (dELISA) that integrates two high-affinity, phage-displayed peptides into a single-molecule array platform, enabling highly sensitive and specific endotoxin detection without the use of antibodies. The carboxylated activation of magnetic beads was optimized using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS) at 10 °C, and L-lysine (Lys) was identified as an effective blocking agent that maintained bead monodispersity through electrostatic repulsion. Under optimized conditions, the assay achieved a detection limit of 0.2 pg mL-1 with a linear range spanning 0-200 pg mL-1. The method exhibited strong accuracy (coefficient of variation (CV) < 15%) and interference resistance (recovery rates of 76.9%-110.1%) when applied to pharmaceutical formulations such as saline, 5% dextrose, and commercial ophthalmic solutions. In clinical validation, the platform successfully quantified endotoxin in plasma samples from septic and non-septic patients and demonstrated excellent recovery (78.0%) in whole blood spiked with exogenous endotoxin. By eliminating antibody-related limitations, this peptide-based dELISA offers a robust and translational tool for direct endotoxin detection in complex biological matrices.

Для цитирования: Li Junrong, Cao Kun, Yang Heqing, Dong Jicheng, Wang Quanwu, Hai Feng. Peptide-based digital ELISA with single-molecule arrays for ultrasensitive and specific endotoxin detection in clinical plasma and pharmaceutical products.. The Analyst. 2026. DOI: 10.1039/d6an00937a.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.