A new material to prevent urethral damage after implantation of artificial devices: an experimental study.

Lima Salvador Vilar Correia, Machado Marcilio Romero, Pinto Flávia Cristina Morone, Lira Mariana Montenegro de Melo, Albuquerque Amanda Vasconcelos de, Lustosa Eugênio Soares, Silva Jaiurte Gomes Martins da, Campos Olávio

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To validate the application of the bacterial cellulose (BC) membrane as a protecting bar-rier to the urethra.

MATERIALS AND

METHODS

Forty female Wistar rats (four groups of 10): Group 1 (sham), the urethra was dissected as in previous groups and nothing applied around; Group 2, received a 0.7cm strip of the BC applied around the urethra just below the bladder neck; Group 3, received a silicon strip with the same dimensions as in group 2; Group 4, had a combination of 2 and 3 groups being the silicon strip applied over the cellulosic material. Half of the animals in each group were killed at 4 and 8 months. Bladder and urethra were fixed in formalin for histological analysis.

RESULTS

Inflammatory infiltrates were more intense at 4 months at lymphonodes (80% Grade 2), statistically different in the group 2 compared with groups 1 (p=0.0044) and 3 (p=0.0154). At 8 months, all samples were classified as grade 1 indicating a less intense inflammatory reaction in all groups. In group 2, at 8 months, there was a reduction in epithelial thickness (30±1μm) when com-pared to groups 1 (p=0.0001) and 3 (p<0.0001). Angiogenesis was present in groups 2 and 4 and absent in group 3. In BC implant, at 4 and 8 months, it was significant when comparing groups 4 with 1 (p=0.0159).

CONCLUSION

BC membrane was well integrated to the urethral wall promoting tissue remodeling and strengthening based on morphometric and histological results and may be a future option to prevent urethral damage.

Для цитирования: Lima Salvador Vilar Correia, Machado Marcilio Romero, Pinto Flávia Cristina Morone, Lira Mariana Montenegro de Melo, Albuquerque Amanda Vasconcelos de, Lustosa Eugênio Soares, Silva Jaiurte Gomes Martins da, Campos Olávio. A new material to prevent urethral damage after implantation of artificial devices: an experimental study.. International braz j urol : official journal of the Brazilian Society of Urology. 2017. DOI: 10.1590/s1677-5538.ibju.2016.0271.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.