Bispectral Index monitoring of palliative sedation for home withdrawal of tracheostomy ventilation: A case report.

Barclay Greg, Barbato Michael, Yerbury Rachel, Harnish Laura, Miranda Nilda

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Tracheostomy ventilation in motor neurone disease is an uncommon life-sustaining treatment. Best practice is having a plan for ventilation withdrawal, but the literature to guide practice is limited. Case reports have documented standard doses of opioids and benzodiazepines used for sedation in such cases.

CASE: A 49-year-old man was diagnosed with motor neurone disease in 2016. He commenced tracheostomy ventilation in 2018. In 2022 and 2023, planning was undertaken, at the patient's request, for withdrawal of tracheostomy ventilation at home, when he was no longer able to communicate with technology.

CASE PLANNING: Planning included Bispectral Index monitoring prior to cessation of ventilation, ensuring this only occurred when deep sedation was achieved. After ventilation withdrawal in 2023, a retrospective review of medications given and his level of sedation on monitoring was undertaken, with family consent.

OUTCOME: Ventilation withdrawal was initiated after deep sedation was achieved, 6 h after commencing subcutaneous infusions of morphine, midazolam, clonazepam and phenobarbital.

LESSONS: Doses required to achieve acceptable sedation exceeded literature reports. Achieving deep sedation was a longer than expected process.

CONCLUSION

More research using an objective measure of sedation is required, as clinical assessment of sedation in this context is compromised.

Для цитирования: Barclay Greg, Barbato Michael, Yerbury Rachel, Harnish Laura, Miranda Nilda. Bispectral Index monitoring of palliative sedation for home withdrawal of tracheostomy ventilation: A case report.. Palliative medicine. 2024. DOI: 10.1177/02692163241257580.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.