MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0290449

Медицинская библиотека · PloS one · 2023

Numerical calculation and experimental analysis of thermal environment in industrialized aquaculture facilities.

Yang Zhipeng, Li Desheng, Song Jiashuai, Bao Encai, Wang Qiang, Qiu Yue, Wu Zhaoxue

СтатьяПеревод в очереди

Аннотация

With the increasing market demand for high-quality aquatic products, the application of industrialized aquaculture facilities may get more attention. In order to improve the poor performance of thermal insulation, the accuracy of the numerical model was verified in this study through actual measured data. The model verification results shown that the average relative errors of the measured and calculated values of indoor air temperature, water temperature and roof inner surface temperature in the industrialized aquaculture workshop is within 2.5%, it suggested that the numerical calculation results are accurate. Furthermore, the thermal environment and thermal insulation performance of industrialized aquaculture facilities in winter were conducted based on the numerical calculations. After optimized the thermophysical parameters of the workshop enclosure structure, we found that the water body temperature could reach 21°C (which was close to the breeding temperature of grouper (Epinephelinae). Therefore, the numerical calculation method was further used to analyze the energy consumption of aquaculture water in January of a typical year in this area by heating to three constant temperatures (22, 25, and 28°C). When the aquaculture water was heated to the three constant temperature states, it needed to consume 8.56×105, 1.02×106 and 1.22×106 MJ of energy respectively, which were equal to the amount of energy released by the complete combustion of 29.3, 35.1 and 41.8 t standard coal. Moreover, it is concluded that the artificial temperature increase in winter maintains the temperature in the range of 22~25°C to provide the highest heating efficiency. This conclusion can provide theoretical basis and application reference for industrialized aquaculture in winter.

Для цитирования: Yang Zhipeng, Li Desheng, Song Jiashuai, Bao Encai, Wang Qiang, Qiu Yue, Wu Zhaoxue. Numerical calculation and experimental analysis of thermal environment in industrialized aquaculture facilities.. PloS one. 2023. DOI: 10.1371/journal.pone.0290449.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.