Analytical and bioanalytical chemistry · 2020
Improving the chromatographic selectivity of β-lactam residue analysis in milk using phenyl-column chemistry prior to detection by tandem mass spectrometry.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Di Rocco Melissa, Moloney Mary, Haren Deirdre, Gutierrez Montserrat, Earley Seán, Berendsen Bjorn, Furey Ambrose, Danaher Martin
Аннотация
Analyte isobaric interferences can limit the development of a comprehensive analytical method for the quantitative liquid chromatography-tandem mass spectrometry profiling of an important cohort of veterinary drugs. In this work, a selective chromatographic separation was developed for the analysis of 32 β-lactam antibiotic residues (12 penicillins, 14 cephalosporins, five carbapenems and faropenem) in milk samples. A range of analytical columns with different stationary phases and mobile phases were evaluated for retention and separation of the β-lactam compounds. Results showed that, among the columns tested, only phenyl-hexyl could adequately separate ampicillin from cephalexin and amoxicillin from cefadroxil, which had shown isobaric interferences on a number of stationary phases. Chromatography was performed using a water/acetonitrile binary gradient with formic acid and ammonium acetate. The β-lactam residues were extracted from the milk samples using a water:acetonitrile solution and purified by C18 dispersive solid-phase extraction (d-SPE) clean-up, followed by concentration under nitrogen and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) determination. Analytes were monitored in positive electrospray ionisation mode (ESI(+)). Possible interfering matrix effects were overcome by using 13 internal standards. The method was fully validated according to 2002/657/EC guidelines, showing satisfactory performance characteristics. Under within-laboratory reproducibility conditions, trueness and precision ranged from 91 to 130% and from 1.4 to 38.6%, respectively. Decision limits (CCα) were in the range 2.1-133 μg kg-1. Limits of detection (LODs) and quantitation (LOQs) ranged between 0.0090 and 1.5 μg kg-1 and from 0.030 to 5.0 μg kg-1, respectively.