BACKGROUND

This study reports and analyzes a large series of patients with neurosensory deficiency related to the placement of dental implants (DIs) and resulting in liability claims (LCs).

METHODS

From 1998 to 2009, there were 92 LCs related to persistent altered sensation post DI placements in Israel. Patients' demographics, year and source of LCs, interval between the procedure that resulted in a neurosensory deficiency and the LC, qualifications of the surgeon, preoperative imaging modality, DI length, available alveolar bone for DI placement, placement site, timing of DI placement (immediately after tooth extraction or after socket healing), and treatment after the diagnosis of neurosensory deficiency were recorded and analyzed.

RESULTS

There were 21 cases during the first 5 years of the study (mean 4.2/year) and 63 cases (mean 12.6/year) over the following 5 years. Thirty LCs were issued during the second postoperative year and 15 LCs after >5 years. Most LCs (76%) involved procedures that were planned and performed according to radiographs and 24% after computed tomography. Sixty-five percent of the LCs were performed by general dental practitioners and 35% by specialists. More than one DI was performed during the surgical procedure that resulted in a neurosensory deficiency in 73 LCs (79.3%), and the DI was >10 mm in 55 (59.8%) cases.

CONCLUSIONS

LCs for DIs that result in a neurosensory deficiency pose a legal risk to the practitioner long after the injury has occurred.

Для цитирования: Givol Navot, Peleg Oren, Yarom Noam, Blinder Daniella, Lazarovici Towy Sorel. Inferior alveolar neurosensory deficiency associated with placement of dental implants.. Journal of periodontology. 2012. DOI: 10.1902/jop.2012.110599.