MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41593-018-0262-6

Медицинская библиотека · Nature neuroscience · 2018

Electrical spinal cord stimulation must preserve proprioception to enable locomotion in humans with spinal cord injury.

Formento Emanuele, Minassian Karen, Wagner Fabien, Mignardot Jean Baptiste, Le Goff-Mignardot Camille G, Rowald Andreas, Bloch Jocelyne, Micera Silvestro, Capogrosso Marco, Courtine Gregoire

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Epidural electrical stimulation (EES) of the spinal cord restores locomotion in animal models of spinal cord injury but is less effective in humans. Here we hypothesized that this interspecies discrepancy is due to interference between EES and proprioceptive information in humans. Computational simulations and preclinical and clinical experiments reveal that EES blocks a significant amount of proprioceptive input in humans, but not in rats. This transient deafferentation prevents modulation of reciprocal inhibitory networks involved in locomotion and reduces or abolishes the conscious perception of leg position. Consequently, continuous EES can only facilitate locomotion within a narrow range of stimulation parameters and is unable to provide meaningful locomotor improvements in humans without rehabilitation. Simulations showed that burst stimulation and spatiotemporal stimulation profiles mitigate the cancellation of proprioceptive information, enabling robust control over motor neuron activity. This demonstrates the importance of stimulation protocols that preserve proprioceptive information to facilitate walking with EES.

Для цитирования: Formento Emanuele, Minassian Karen, Wagner Fabien, Mignardot Jean Baptiste, Le Goff-Mignardot Camille G, Rowald Andreas, Bloch Jocelyne, Micera Silvestro, Capogrosso Marco, Courtine Gregoire. Electrical spinal cord stimulation must preserve proprioception to enable locomotion in humans with spinal cord injury.. Nature neuroscience. 2018. DOI: 10.1038/s41593-018-0262-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.