m+Medelevator.RU
← Поиск публикаций
American journal of hypertension · 2012

Automated office blood pressure is associated with urine albumin excretion in hypertensive subjects.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Andreadis Emmanuel A, Agaliotis Gerasimos D, Angelopoulos Epameinondas T, Tsakanikas Athanasios P, Kolyvas George N, Mousoulis George P

Аннотация

BACKGROUND: We aimed to investigate the association between automated office blood pressure (AOBP) readings and urine albumin excretion (UAE), and to assess if this association is as close as that between 24-h ambulatory blood pressure (ABP) and UAE. A strong association would suggest that AOBP may serve as an indicator of early renal impairment.

METHODS: In a sample of 162 hypertensives, we compared AOBP with ABP measurements and their associations with UAE in two consecutive 24-h urine collections measured by an immunoturbidimetric assay. Microalbuminuria was defined as UAE of 30-300 mg/24 h.

RESULTS: The age of the subjects was 53 ± 13 (mean ± s.d.) years. Twenty-two were microalbuminuric. In those, AOBP and 24-h ABP were higher than in the normoalbuminuric subjects: 152 ± 19 and 147 ± 20 vs. 138 ± 15 and 130 ± 11 mm Hg for systolic blood pressure (SBP), and 97 ± 15 and 92 ± 14 vs. 86 ± 10 and 82 ± 8 mm Hg for diastolic blood pressure (DBP) (P < 0.001). Correlations between AOBP and 24-h ABP with log-transformed urine albumin were 0.30 (P < 0.001) and 0.43 (P < 0.001) for SBP and 0.27 (P < 0.001) and 0.33 (P < 0.001) for DBP. Adjusting for age, sex, body mass index, and estimated glomerular filtration rate, both AOBP and 24-h ABP were independently associated with urine albumin (P < 0.001 for both associations). Receiver operating characteristics curve analysis showed a similar predictive ability for microalbuminuria for AOBP and for 24-h ABP (area under the curve: 0.819 (P < 0.001) for SBP, 0.836 (P < 0.001) for DBP vs. 0.830 (P < 0.001) for SBP and 0.845 (P < 0.001) for DBP).

CONCLUSIONS: In this study, microalbuminuria correlated similarly with high-quality AOBP and ABP readings, further supporting the use of AOBP in the clinical setting.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты