Physician Modification to Shorten a TAG Thoracic Endoprosthesis for Treatment of a Pseudoaneurysm in the Ascending Aorta.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wada Kenji, Shimamoto Takeshi, Komiya Tatsuhiko, Tsuneyoshi Hiroshi
Аннотация
PURPOSE: To report initial use of a physician-modified Gore TAG Thoracic Endoprosthesis for the treatment of pseudoaneurysm in the ascending aorta.
TECHNIQUE: This technique is demonstrated in a 42-year-old man with a pseudoaneurysm of the ascending aorta after a Bentall operation. The treatable length extending from the sinotubular junction to the anastomotic aneurysm edge was only 5 cm. A 45×100-mm TAG endograft for the pseudoaneurysm was modified on a back table to shorten its length. The delivery shaft was incised, and the 2 threads that fasten the top and bottom portions of the stent-graft to the sleeve were pulled out. The unfolded half of the stent-graft was cut back after pulling out the strand for the back half. Next, this custom-made graft was deployed via a transcarotid approach with cardiopulmonary bypass; no endoleak was observed. Postoperative computed tomography showed a minute type Ib endoleak. The patient was doing well at postoperative month 6.
CONCLUSION: Physician modification of a TAG endograft facilitated effective management of this ascending aortic lesion by shortening the length of aortic coverage.
TECHNIQUE: This technique is demonstrated in a 42-year-old man with a pseudoaneurysm of the ascending aorta after a Bentall operation. The treatable length extending from the sinotubular junction to the anastomotic aneurysm edge was only 5 cm. A 45×100-mm TAG endograft for the pseudoaneurysm was modified on a back table to shorten its length. The delivery shaft was incised, and the 2 threads that fasten the top and bottom portions of the stent-graft to the sleeve were pulled out. The unfolded half of the stent-graft was cut back after pulling out the strand for the back half. Next, this custom-made graft was deployed via a transcarotid approach with cardiopulmonary bypass; no endoleak was observed. Postoperative computed tomography showed a minute type Ib endoleak. The patient was doing well at postoperative month 6.
CONCLUSION: Physician modification of a TAG endograft facilitated effective management of this ascending aortic lesion by shortening the length of aortic coverage.