MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12574-023-00626-8

Медицинская библиотека · Journal of echocardiography · 2023

Optimal left ventricular diameter measurement in subjects with sigmoid septum: comparison with three-dimensional left ventricular volume.

Okada Kazunori, Nakabachi Masahiro, Hayashi Yasuhiro, Shinagawa Masaaki, Yoshikawa Ayaka, Tsujita Kosuke, Sakamoto Yoichi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to determine the most appropriate measurement of left ventricular (LV) end-diastolic diameter for subjects with the sigmoid septum (SS) by measuring the LV end-diastolic diameter at the base and mid-ventricle and by examining the relationship between these measurements and the three-dimensional (3D) echocardiographic LV end-diastolic volume.

METHODS

In 91 patients who underwent echocardiography for screening cardiovascular abnormalities, the aorto-septal angle (ASA) was measured as an index of the sigmoid septum. LV end-diastolic diameter was measured at the base and mid-ventricular level (DDbase and DDmid, respectively), and their average value was calculated (DDavg). By using 3D echocardiography, LV end-diastolic volume (EDV3D) was measured.

RESULTS

Among 91 patients, 48 patients had narrow ASA (< 120 degrees) and were divided into the sigmoid septum (SS) group, and the remaining 43 patients were divided into the non-SS group. In the SS group, all DDbase, DDmid, and DDavg were significantly correlated with EDV3D (r = 0.59, 0.80, and 0.76, respectively), and the correlation coefficient between DDbase and EDV3D was significantly lower than that between DDmid and EDV3D (p < 0.01). On the other hand, in the non-SS group, all DDbase, DDmid, and DDavg were significantly correlated with EDV3D (r = 0.77, 0.85, and 0.84, respectively), and the correlation coefficient between DDbase and EDV3D was statistically comparable to that between DDmid and EDV3D (p = 0.12). ASA was significantly correlated with the difference of DDmid minus DDbase (r =  - 0.71, p < 0.001).

CONCLUSIONS

In patients with SS, DDmid and DDavg were well reflected the 3D echocardiographic LV end-diastolic volume.

Для цитирования: Okada Kazunori, Nakabachi Masahiro, Hayashi Yasuhiro, Shinagawa Masaaki, Yoshikawa Ayaka, Tsujita Kosuke, Sakamoto Yoichi. Optimal left ventricular diameter measurement in subjects with sigmoid septum: comparison with three-dimensional left ventricular volume.. Journal of echocardiography. 2023. DOI: 10.1007/s12574-023-00626-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.