DOI 10.1177/0300060520901872

Медицинская библиотека · The Journal of international medical research · 2020

Efficacy of intracuff lidocaine in reducing coughing on tube: a systematic review and meta-analysis.

Peng Fei, Wang Maohua, Yang Huihuang, Yang Xiaoli, Long Menghong

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

OBJECTIVE

To investigate the efficacy of intracuff lidocaine in reducing coughing and other endotracheal tube side effects and so ensure a smooth extubation process.

METHOD: PubMed, EMBASE, and Cochrane Library databases were systematically searched for all randomised controlled trials (RCTs) published before June 30, 2019 that investigated the efficacy of intracuff lidocaine, with or without sodium bicarbonate, in reducing coughing and other complications related to endotracheal intubation. A random-effects model was used to conduct a meta-analysis to assess the relative risks (RRs) of the incidence of these intubation-related side effects.

RESULTS

11 studies involving 843 patients were included in the meta-analysis. Compared with control groups (i.e., saline or air), intracuff lidocaine groups (alkalinized or non-alkalinized) had a significantly reduced incidence of coughing on tube. Similarly, intracuff lidocaine groups were more effective than control groups in reducing the incidence of other intubation-related complications.

CONCLUSION

Intracuff alkalinized or non-alkalinized lidocaine significantly reduced coughing and other intubation-related complications during the extubation process.

Для цитирования: Peng Fei, Wang Maohua, Yang Huihuang, Yang Xiaoli, Long Menghong. Efficacy of intracuff lidocaine in reducing coughing on tube: a systematic review and meta-analysis.. The Journal of international medical research. 2020. DOI: 10.1177/0300060520901872.