MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/08037051.2012.686180

Медицинская библиотека · Blood pressure · 2012

Variability and concordance of Cornell and Sokolow-Lyon electrocardiographic criteria in hypertensive patients.

Vinyoles Ernest, Rodriguez-Blanco Teresa, de la Figuera Mariano, Colomé Josep M, Tafalla Marta, Calbet Núria, Fernández-San Martin M Isabel, García-Alonso Judit, Murillo Cristina, Agudo Josep

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To assess the variability and concordance of left ventricular hypertrophy electrocardiographic (LVH-ECG) criteria.

METHODS AND

RESULTS

Convenience sampling of hypertensive subjects without coronary disease or bundle branch blocks. Two electrocardiograms (ECGs) were performed on each patient. Two investigators carried out two blind-readings of each ECG (Cornell and Sokolow-Lyon criteria). The between-rater and within-rater reliability were assessed (intraclass correlation coefficient, ICC). Poor concordance was defined: mean voltage difference between both ECGs >2 mm; 824 ECG readings were performed in 103 subjects (58.3% females), aged 66.8±8.8 years, mean blood pressure 141±15.10/78±9.0 mmHg. The between-rater ICCs of the baseline ECG were 0.97(95% CI 0.96-0.98) and 0.98 (95% CI 0.97-0.99) for Cornell and Sokolow-Lyon criteria, respectively. Poor concordance was found in 39.8% and in 41.7% of the cases for Cornell and Sokolow-Lyon criteria, respectively. Systolic blood pressure was found to be significant and positively associated with both criteria. Elderly hypertensive subjects, with higher ECG voltages and lower pulse pressure presented poor concordance of Cornell criteria.

CONCLUSIONS

The between-rater and within-rater reliability of Cornell and Sokolow-Lyon criteria is minimal. Approximately 40% of hypertensive subjects presented poor concordance in a second ECG. Older patients with lower pulse pressure and higher baseline voltages presented poorer reproducibility of LVH-ECG criteria.

Для цитирования: Vinyoles Ernest, Rodriguez-Blanco Teresa, de la Figuera Mariano, Colomé Josep M, Tafalla Marta, Calbet Núria, Fernández-San Martin M Isabel, García-Alonso Judit, Murillo Cristina, Agudo Josep. Variability and concordance of Cornell and Sokolow-Lyon electrocardiographic criteria in hypertensive patients.. Blood pressure. 2012. DOI: 10.3109/08037051.2012.686180.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.