Journal of orthopaedic trauma · 2006
A randomized, controlled trial of distal radius fractures with metaphyseal displacement but without joint incongruity: closed reduction and casting versus closed reduction, spanning external fixation, and optional percutaneous K-wires.
Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kreder Hans J, Agel Julie, McKee Michael D, Schemitsch Emil H, Stephen David, Hanel Douglas P
Аннотация
OBJECTIVES: To compare closed reduction and casting with closed reduction and external fixation with optional K-wire fixation for distal radius fractures with metaphyseal displacement but without joint incongruity.
DESIGN: Prospective study.
SETTING: Multicenter study at 3 University teaching hospitals.
PATIENTS/PARTICIPANTS: A total of 113 skeletally mature patients with distal radius fractures with metaphyseal displacement, but without joint incongruity, were randomized to receive 1 of 2 standardized treatment protocols. Patients were evaluated at 6 weeks, 6 months, 1 year, and 2 years.
INTERVENTION: Closed reduction and casting (n = 59) or closed reduction and external fixation (n = 54).
MAIN OUTCOME MEASUREMENTS: Upper extremity function was measured using upper extremity MFA domain scores, overall Jebsen Taylor scores, and pinch and grip strength tests. Global function and pain were measured using the SF-36. Radiographic evaluation and range of motion were documented.
RESULTS: Upper extremity MFA scores, Jebsen Taylor scores, SF-36 bodily pain scores, and grip strength improved significantly during the first year for all patients. By 2 years, mean Jebsen Taylor scores and SF 36 bodily pain scores for patients in both groups were similar to scores for normal age- and gender-matched population controls. At all points, there was a trend for better function in the external fixation; however, this did not reach statistical significance. There was a trend for better length and palmar tilt restoration with external fixation.
CONCLUSIONS: For distal radius fractures with metaphyseal displacement but with a congruous joint, there exists a trend for better functional, clinical, and radiographic outcomes when treated by immediate external fixation and optional K-wire fixation.
DESIGN: Prospective study.
SETTING: Multicenter study at 3 University teaching hospitals.
PATIENTS/PARTICIPANTS: A total of 113 skeletally mature patients with distal radius fractures with metaphyseal displacement, but without joint incongruity, were randomized to receive 1 of 2 standardized treatment protocols. Patients were evaluated at 6 weeks, 6 months, 1 year, and 2 years.
INTERVENTION: Closed reduction and casting (n = 59) or closed reduction and external fixation (n = 54).
MAIN OUTCOME MEASUREMENTS: Upper extremity function was measured using upper extremity MFA domain scores, overall Jebsen Taylor scores, and pinch and grip strength tests. Global function and pain were measured using the SF-36. Radiographic evaluation and range of motion were documented.
RESULTS: Upper extremity MFA scores, Jebsen Taylor scores, SF-36 bodily pain scores, and grip strength improved significantly during the first year for all patients. By 2 years, mean Jebsen Taylor scores and SF 36 bodily pain scores for patients in both groups were similar to scores for normal age- and gender-matched population controls. At all points, there was a trend for better function in the external fixation; however, this did not reach statistical significance. There was a trend for better length and palmar tilt restoration with external fixation.