MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajem.2015.12.016

Медицинская библиотека · The American journal of emergency medicine · 2015

Ultrasound-guided nerve blocks for intracapsular and extracapsular hip fractures.

Dickman Eitan, Pushkar Illya, Likourezos Antonios, Todd Knox, Hwang Ula, Akhter Saadia, Morrison Sean

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVES

To compare pain relief between patients with intracapsular and extracapsular hip fractures who received an ultrasound-guided femoral nerve block (USFNB).

DESIGN

A multicenter, prospective, randomized, clinical trial.

SETTING

The study was conducted in the emergency departments of 3 academic hospitals located in New York City.

SUBJECTS: Patients aged ≥60 years presenting to the emergency department with hip fracture.

METHODS

A subgroup analysis from a larger data set was conducted of patients with intracapsular and extracapsular hip fractures who received an USFNB. We compared pain scores at baseline and then at 2 and 3 hours after the nerve block was performed, and also assessed pain relief at 2 and 3 hours.

RESULTS

Seventy-seven patients were randomized to receive USFNB, of which 68 had follow-up data at 2 and 3 hours and were included in the data analysis. Thirty-one were diagnosed with intracapsular and 37 with extracapsular hip fractures. In both groups, reductions in pain scores were clinically and statistically significant. In the intracapsular group, mean pain scores decreased from 6.23 to 3.81 (P < .0001) at 2 hours and from 6.23 to 3.87 (P < .0001) at 3 hours. In the extracapsular group, mean pain scores decreased from 6.62 to 3.89 (P < .0001) at 2 hours and from 6.62 to 3.46 (P < .0001) at 3 hours. These differences were similar between the extracapsular and intracapsular groups at 2 hours (P = .92) and at 3 hours (P = .58), thus demonstrating similar reductions in pain in the 2 groups. The differences in pain relief between the intracapsular and extracapsular groups were also similar: 1.61 (confidence interval [CI], 1.14-2.08) vs 1.35 (CI, 0.96-1.75) at 2 hours (P = .39) and 1.68 (CI, 1.21-2.15) vs 1.38 (CI, 0.89-1.87) at 3 hours (P = .38).

CONCLUSION

Ultrasound-guided femoral nerve block was equally effective in reducing pain for patients with both intracapsular and extracapsular hip fractures.

Для цитирования: Dickman Eitan, Pushkar Illya, Likourezos Antonios, Todd Knox, Hwang Ula, Akhter Saadia, Morrison Sean. Ultrasound-guided nerve blocks for intracapsular and extracapsular hip fractures.. The American journal of emergency medicine. 2015. DOI: 10.1016/j.ajem.2015.12.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.